CHAPTER 433 THE ELECTRICITY ACTCHAPTER 433

THE ELECTRICITY ACT

 

 

ARRANGEMENT OF SECTIONS

 

 

PART I

PRELIMINARY

 

 

Section

  1.          Short title

  2.          Interpretation

 

 

PART II

ELECTRICITY GENERATION, TRANSMISSION, DISTRIBUTION
AND SUPPLY

 

 

  3.          With certain exceptions, undertaking to comply with law

  4.          Establishment of undertakings

  5.          Increase or decrease of rated generating capacity

  5A.       Purchase of power from outside Zambia

  6.          Duties of operator of undertaking as to supply

  7.          Charges for supply

  8.          Variations and alterations of charges

  9.          Contract of supply must be carried out

10.          Failure to carry out contract of supply

11.          Revocation of licences

12.          Maintenance of undertakings

13.          Supply within area of local authority

 

 

PART III

ACQUISITION OF LAND AND RIGHTS OVER LAND

 

 

14.          Acquisition of land for electricity purposes

15.          Wayleaves over Land

16.          Rights of entry

17.          Trees and buildings interfering with transmission lines

18.          Obstruction of lines by buildings, etc.

19.          Breaking up of streets

20.          Compensation for damage in the exercise of powers

 

 

PART IV

OFFENCES AND PENALTIES

 

 

Section

21.          Interference with supplies and apparatus

22.          False information

23.          Contraventions of Act

24.          Penalties

 

 

PART V

GENERAL

 

 

25.          Entry and inspection

26.          Operator's powers of entry and inspection

27.          Information and records

28.          Notice of accidents

29.          Serving of notice

30.          Regulations

 

 

31.          Repeal of Cap. 811

 

 

CHAPTER 433

 

 

ELECTRICITY

 

Act No.
15 of 1995

21 of 2003

 

An Act to regulate the generation, transmission, distribution and supply of electricity; and to provide for matters connected with or incidental to the foregoing.

[28th April, 1995]

 

 

PART I

PRELIMINARY

 

 

1.    This Act may be cited as the Electricity (Amendment) Act, 2003, and shall be read as one with the Electricity Ac, in this Act referred to as the principal Act.

 

Short title

Cap. 43

2.    In this Act, unless the context otherwise requires-

Interpretation

"Board" means the Energy Regulation Board established by the Energy Regulation Act;

"common carrier" means a transmission line or distribution line declared as such by the Minister under this Act;

Cap. 436

"contract of supply" means a contract between the operator of an undertaking and any other person for the supply of electricity to that person;

 

"consumer" means a person to whom electricity is supplied under a contract of supply;

"distribution" means the transportation of electricity on high voltage, medium voltage and low voltage systems for delivery to the final consumers but does not include supply;

"distribution line" means any cable, overhead or underground line for the transportation of electricity on high voltage, medium voltage and low voltage systems and includes-

(a) any transfer, swithgear or other works necessary for, and used in connection with, such cable,  overhead or underground line; and

(b) any buildings or any part of such building as may be required to accommodate such transformer, switchgear or other works;

"generation" means the production of electricity

 

"generating station" means any station for generating electricity including any building, plant and machinery used for the purpose and all accessories necessarily incidental thereto, together with the site thereof, and any site intended to be used for such a station;

"interconnected system" means a number of transmission and distribution lines which are linked together;

 

"land" includes any land under whatever tenure held and any easement, servitude, right or privilege in or over land or water;

 

"local authority" means a council established under the Local Government Act;

Cap. 281

 

"owner"-

 

 

(a)        in relation to State Land, means the President, Minister or other authority who is authorised to deal with matters relating to State Land;

 

 

(b)        in relation to land other than State Land, includes-

 

 

(i)         the person known to be representative in Zambia of the owner of the land;

 

(ii)        the liquidator or receiver of a company that owns land; and

 

(iii)       the representative recognised by law of any owner who has died or become bankrupt, is an assignee of an estate, or is a minor or of unsound mind or otherwise under a disability;

 

"rated generating capacity", in relation to installed generating plant, means the designed maximum continuous output of the plant;

 

"State Land" has the meaning assigned to it in the Lands Act;

Cap. 184

"street" means any road or highway or any part of a road or highway, whether or not it has been at any time declared or rendered such by some competent authority, and includes bridges over which a street passes and any drift in the line of a street and all approaches, cuttings, embankments, subways, culverts, sluits, drains, dams, kerbs, fences, parapets, guards, grid-iron tracks, and other work or thing forming part of, or connected with, or belonging to, such street, and includes any sanitary lane or private street;

 

"supply" means the sale of electricty to consumers;

 

"transmission" means the transportation of electricity on an extra high voltage or high voltage interconnected system for delivery to ditributors and final consumers but does not include supply;

"transmission line" means any cable or overhead line for the transmission or reticulation of electricity from one undertaking to another or from an undertaking to a consumer, together with any transformers, switchgear and other works necessary to, and used in connection with, such cable or overhead line, and the buildings such part thereof as may be required to accommodate such transformers, switchgear and other works;

 

 

"undertaking" means any undertaking for the generation, transmission, distribution or supply of electricity, and includes such an undertaking that generates, transmits, distributes or supplies electricity solely or mainly in the interests of a group of associated companies for the purpose of the businesses of those companies, whether or not any excess electricity is supplied to any other consumer who is not part of the group.

 

(As amended by Act No. 21 of 2003)

PART II

ELECTRICITY GENERATION, TRANSMISSION, DISTRIBUTION AND SUPPLY

 

 

3.  (1)  Subject to subsection (2) and the Energy Regulation Act, no person shall establish or carry on any undertaking unless in accordance with this Act and the Energy Regulation Act.

With certain exceptions, Undertaking to comply with law
Cap. 436

(2)  Subsection (1) shall not apply to an undertaking the plant of which is rated at the site where it is installed at a capacity of less than one hundred kilowatts and which is a company of less than one hundred kilowatts and which is used solely for the generation, transmission, distribution or supply of electricity for an operator's own use.

 

4.  (1)  Any person who wishes to erect and establish any generating station works-

Establishment of undertakings

(a)        the plant of which will be rated at the site where it is to be installed at a capacity of one hundred or more kilowatts, for generating, transmitting, transforming, converting or distributing electricity; or

 

(b)        the plant of which is rated at the site where it is installed at a capacity of less than one hundred kilowatts and which is used for the generation, transmission, distribution or supply of electricity for the use of any other person, whether or not it is for an operator's own use;

shall do so in accordance with regulations made under this Act, and shall comply with any requirement of the Board for the purpose of facilitating co-ordination with existing or future undertakings.

 

(2)  The Minister may, by statutory instrument, declare any transmission line to be a common carrier for the purposes of this Act.

 

(3)  A transmission line that is declared, under subsection (2), to be a common carrier may, subject to any regulations made under this Act and any requirements made by the Board under subsection (1), be used for the purposes of an undertaking on such terms and conditions as may be agreed between the operator of the undertaking and the owner or person in control of the line concerned or, in default of such agreement, as may be determined by the Board with the consent of the Minister.

 

(As amended by Act No. 21 of 2003)

5.  (1)  If any undertaking which is part of an interconnected system wishes to increase or decrease its related generating capacity,  it shall apply to the Board for approval and shall submit to the Board a full report on its proposals.

Increase or decrease of rated generating capacity

(2)  The Board shall after considering an application submitted under section (1) approve or refuse tp approve the application.

 

(3)  Where the Board refused an application under subsection (2), the Board shall within fourteen days of making the decision notify the applicant, in writing, stating the reasons for the refusal to approve the application.

(4) Any person who is aggrieved by the refusal of the Board to approve an application under subsection(1) may appeal to the Minister within thirty days of receiving the notification.

(5) The Minister shall, within thirty days of receiving the appeal under subsection (4), consider the appeal.

(6) In any appeal under subsection (4) the Minister may confirm or set aside the decision of the Board and shall immediately notify the appellant of the Minister's decision.

(7) Any person who is aggrieved by the Minister's decision under subsection (6) may, within thirty days of receiving the notification, appeal to the High Court.

(As amended by Act No. 21 of 2003)

 

 

5A. (1) Any undertaking which wishes to purchase power from outside Zambia shall apply to the Minister for Approval and shall submit to the Minister a full report on its proposals.

 

(2) The Minister shall, in considering any application under subsection (1), have regard to the terms of any relevant international agreement and to the advice of the Board.

 

(3) The Minister may, after considering a report submitted under subsection (1), approve or refuse to approve the application.

 

(4) Where the Minister refuses to approve an application under subsection (3) the Minister shall within fourteen days of making the decision notify the applicant, in writing, stating the reasons for the refusal.

 

(5) Any person aggrieved by the refusal of the Minister to approve an application under this section may appeal to the High Court within thirty days of receiving the notification.

 

(As amended by Act No. 21 of 2003)

Purchase of power from outside Zambia

 

6.  (1)  Subject to the terms and conditions of a licence issued in accordance with the Energy Regulation Act, every operator of an undertaking shall supply electricity to every consumer who is in a position to make satisfactory arrangements for payment under a contract of supply with that operator.

Duties of operator of undertaking as to supply
Cap. 436

(2)  Where an operator of an undertaking unduly delays or refuses to supply any applicant with electricity, the consumer may appeal to the Board, which shall determine the conditions under which the operator shall undertake such supply.

 

(3)  A person who is supplied with electricity from an operator of an undertaking shall not be entitled to a standby supply of electricity from the operator in respect of any premises unless that person has agreed to pay, and has given security to pay, such minimum annual sum as will give to the operator a reasonable return on any capital expenditure and any other standing charges which may be incurred in meeting the maximum demand for the premises.

 

7.    Subject to section eight, the charges made by an operator of an undertaking that supplies electricity to the public shall be determined in accordance with the licence governing the undertaking.

Charges for supply

8.  (1)  Subject to other provisions of this section, an operator of an undertaking that supplies electricity to the public may, with due regard to any or all of the following circumstances:

Variations and alterations of charges

(a)        the amount of electricity consumed;

 

(b)        the uniformity or regularity of demand;

 

(c)        the time when or during which the electricity is required;

 

(d)        the expenditure of the operator of the undertaking in furnishing supply;

 

(e)        any other circumstances approved by the Board;

vary prices in respect of the supply of electricity to a particular consumer either above or below the charges specified in the licence governing the undertaking and may, from time to time, alter the charges so varied.

 

(2)  If an operator considers it expedient to vary or alter charges in respect of any supply of electricity, the operator shall give notice to the consumer of the proposal to vary or alter those charges, as the case may be.

 

(3)  If the consumer does not make any application under subsection (4) within thirty days of the date of notice referred to in subsection (2), the variation or alteration, as the case may be, shall, unless the operator of the undertaking and the consumer otherwise agree, come into effect thirty days after the date of that notice or from such later date as the operator may in that notice fix.

 

(4)  The Board shall, on an application by a consumer, review a proposal referred to in subsection (2), taking into consideration any submissions made by the consumer.

(4A) The Board may, if it considers it appropriate, on its own motion review a notice by an operator of undertaking to vary or alter charges inrespect of any supply of electricity.

 

(5)  Any application made under subsection (4), together with any objection of the operator to that application, shall be submitted to the Board.

 

(6)  Any consumer who makes an application under subsection (4), or the operator of any undertaking who objects to such an application, may, either by themselves or by their legal practitioner, appear before the Board and lead evidence in support of the application or objection, as the case may be.

 

(7)  After considering the application referred to in subsection (4) and any objection thereto, the Board may-

 

(a)        confirm the proposed variation or alteration, as the case may be, to which the application relates;

 

(b)        order that the proposed variation or alteration, as the case may be, to which the application relates shall not be made; or

 

(c)        order the operator of the undertaking to make such other variation or alteration, as the case may be, as the Board considers fit.

 

(As amended by Act No. 21 of 2003)

9.    Except for causes beyond the control of the operator of an undertaking, and subject to any regulations made under this Act, no operator shall lessen or discontinue the supply of electricity stipulated in any contract of supply unless-

(a)        the consumer has failed to pay charges lawfully due in terms of the conditions of supply or the agreement, as the case may be; or

(b)        the consumer has failed to comply with conditions of supply or the regulations and failed to remedy the default within seven days of receiving, from the operator of the undertaking, a notice served on the consumer in accordance with section twenty-nine calling upon the consumer to do so.

(As amended by Act No. 21 of 2003)

Contract of supply must be carried out

 

10.  (1)  If any operator of an undertaking wilfully or without reasonable cause lessens or discontinues the supply of electricity stipulated in any contract of supply, or if a person operates an undertaking in such a manner as is, in the opinion of the Board, detrimental to the public interest, the Board may, after affording the operator an opportunity to be heard on the matter, suspend the licence and authorise any person appointed by the Board to enter upon the undertaking and forthwith to take all such action as that person may consider necessary for the maintenance and continuation of the supply of electricity from the undertaking.

Failure to carry out contract of supply

(2)  The person appointed under subsection (1) shall operate the undertaking for, and on account of, and at the risk and expense of, the operator thereof, and shall, after deducting such amount, in payment of the reasonable costs and expenses of operating the undertaking, as the Board may approve, render the balance of the net revenue derived from the undertaking to such operator.

 

(3)  Any entry made under this section shall not prejudice or affect the security of any debenture holder or mortgage or the right of enforcing such security.

 

(4)  Where the Board takes action under subsection (1), the Board shall not remove the suspension of the licence until the Board is satisfied that the causes for which the licence was suspended have been removed.

 

(5)  Notwithstanding the foregoing provisions of this section, if the estate of the operator of an undertaking has been the subject of a receiving order made under any law relating to bankruptcy, the undertaking shall not, save with the consent of the receiver or trustee, as the case may be, be operated for a period longer than ninety days and the taking over of control of the undertaking under the provisions of the section shall not deprive such receiver or trustee of the right to dispose of the undertaking for the benefit of the creditors.

 

11.  (1)  Where the operator of an undertaking fails to remove the causes for which the licence authorising the undertaking was suspended within ninety days of the suspension, the operator shall be deemed to be in default for the purposes of section fifteen of the Energy Regulation Act, and the Board may, after affording the operator an opportunity to be heard on the matter either directly or through a legal practitioner, revoke the licence in accordance with the provisions of this Act.

Revocation of licences
Cap. 436

(2)  In the event of a licence being revoked under this section, the Board may authorise any person appointed by the Board to enter upon the undertaking of the person concerned and operate it in accordance with the provisions of this Act, but no such entry shall prejudice or affect the security of any debenture holder or mortgage or the right of enforcing such security.

(3) Any operator who is aggrieved by the decision of the Board to revoke its licence may within thirty days of receiving the notification appeal to the High Court.

(As amended by Act No. 21 of 2003)

 

 

12.    Any person who operates an undertaking the plant of which is rated at the site where it is installed at a capacity of one hundred or more kilowatts shall submit to the Board details of the plant and installation of the undertaking in such manner and form as the Board may prescribe, and any such undertaking shall be maintained in accordance with regulations made under this Act, and shall comply with any requirement of the Board for the purpose of facilitating co-ordination with existing or future undertakings.

(As amended by Act No. 21 of 2003)

Maintenance of undertakings

 

13.  (1)  A licence under the Energy Regulation Act authorising any person to supply electricity within the area under the jurisdiction of a local authority shall not be issued-

(a) without the consent of that authority; and

Supply within area of local authority
Cap. 436

(b) in the absence of an environmental impact assessment report.

(2)  In paragraph (b) of subsection (1) "environmental impact assessment reprot" means an environment impact assessment report issued by the Environmental Council of Zambia inaccordance with the provisions of the Environmental Protection and Pollution control Act.

(As amended by Act No. 21 of 2003)

 

 

 

Cap.204

 

PART III

ACQUISITION OF LAND AND RIGHTS OVER LAND

 

 

14.  (1)  The President may, by order, authorise the acquisition by compulsion of so much land, including State Land, as the President may consider necessary for any purpose associated with the generation, transmission, distribution or supply of electricity by an operator of any undertaking and any acquisition in terms of this section shall be completed in accordance with such directions as the President may give in that or any other order.

Acquisition of land for electricity purposes

(2)  Before making an order under subsection (1), the President shall be satisfied that-

 

(a)        the operator concerned has taken all reasonable steps to acquire the land intended to be used on reasonable terms by agreement with the owner of the land and has been unable to do so; and

 

(b)        the acquisition of such land is necessary for the purposes of the undertaking carried on by the operator concerned.

 

(3)  The President may, under such conditions as the President may consider necessary, including conditions requiring the reimbursement of compensation paid under subsection (4), permit the use by the operator of any undertaking of any land which the President has acquired under subsection (1):

 

Provided that-

 

(a)        the land shall not be used by that operator for any purpose other than the purpose for which it was acquired under subsection (1); and

 

(b)        the land or such part of it as the President may determine shall revert to the use and absolute control of the President if it or any part of it is not used for any purpose for which it was acquired under subsection (1).

 

(4)  Adequate compensation shall, from moneys appropriated for the purpose by Parliament, be paid to any person who suffers loss or damage through the exercise of the powers conferred by this section in accordance with the provisions of the Lands Acquisition Act.

 

 

 

Cap. 189

(5)  An application for an order under this section shall be made in the manner prescribed, and a copy of each application shall be served on the owner of the land and on any person lawfully occupying it if such owner or person is, at the time of the application, resident within Zambia.

 

(6)  If the owner of, or any person lawfully occupying, any land to be acquired under this section is temporarily absent from Zambia at the time when an order is made, any person authorised by the President so to act may enter upon, take possession of, and use, such land, leaving all questions as to the compensation to be paid for such land to be settled afterwards in accordance with subsection (4).

 

(7)  Where any rights over land have been acquired by the operator of an undertaking, whether by agreement or under this Part, then, notwithstanding the fact that those rights may not have been registered against the title to the land to which they relate in accordance with the written law relating to registration of title, those rights shall be binding on the owner of such land and on the successor in title or representative in interest.

(As amended by Act No. 21 of 2003)

 

 

15.  (1)  Notwithstanding section fourteen, the operator of an undertaking may, subject to the provisions of this section, place transmission line, whether above or below ground, into, out of, or across, any land including State Land, other than land covered by buildings.

Wayleaves over land

(2)  Before placing any line in position in accordance with subsection (1), the operator shall serve on the owner of the land and any person lawfully occupying it or, in the case of a street, on the local or other authority concerned, notice of the intention to erect a line, together with a description of the lines proposed to be placed:

 

Provided that if the owner or such person is not resident or has no representative within Zambia, no such notice need be served.

 

(3)  If, within twenty-eight days after the service of a notice under subsection (2), the person to whom such notice has been given objects, or attaches to the consent any terms or conditions to which the operator of the undertaking objects, the operator may refer the matter to the Minister for decision, and the Minister may make such order as may be necessary:

 

Provided that any question as to an amount of compensation shall, with any necessary modifications, be decided in accordance with subsection (4) of section fourteen.

 

(4)  Nothing contained in this section shall authorise or empower the operator of an undertaking to lay down or place any transmission line into, through, or against any building, or in any land above which a building is erected, without the consent of the owner and lawful occupier thereof:

 

Provided that any overhead line and any support, stay or strut required for the sole purpose of supporting an overhead line may be placed on or above any land or building with the consent of the Minister if, in the minister' opinion, the consent of the owner or person lawfully occupying the land, as the case may be, is being unreasonably withheld, and the Minister shall fix the amount of compensation or of annual rental, or of both, which shall be paid to such owner or such person by the operator.

 

(5)  If the owner of, or person lawfully occupying, any land on or over which any transmission line has been placed, or in the case of a street, the local or other authority concerned, requires the position of such line to be changed, the Minister may, by notice in writing, order the operator to alter the position of such line, subject to such conditions as failing agreement between the parties, may be specified by the Minister.

 

16.  (1)  When, in accordance with the provisions of this Part, the operator of an undertaking has been permitted to use any land or has placed a transmission line in position, the operator shall be entitled to reasonable access to such land or line for the purpose of carrying on the operations authorised by his licence on such land or maintaining, removing, repairing or replacing such line.

Rights of entry

(2)  When the operator of any undertaking has acquired any land or rights over land under the provisions of any written law relating to the supply of electricity, the provisions of subsection (1) shall apply, with necessary modifications, to access to such land, and any person entitled to exercise them, subject to the conditions applicable to them under the provisions of the law at the time when they were required.

(As amended by Act No. 21 of 2003)

 

 

17.  (1)  Where on any land, including State Land, trees or undergrowth obstruct or interfere with the construction, working or maintenance of any transmission line, the operator concerned may give to the owner or lawful occupier of the land upon which such trees or undergrowth are situated not less than fourteen days' notice of intention to enter upon the land and cut down or trim the trees or undergrowth in question and, after expiry of such notice, may enter upon land and carry out such intention:

Trees and buildings interfering with transmission lines

Provided that, after receiving notice in terms of this subsection, the owner or lawful occupier upon whom it was served may, at his own expense and at any time before the expiry of the notice, cut down or trim the trees or undergrowth in question to the extent indicated by the operator.

 

(2)  Notwithstanding subsection (1), if immediate action is imperative to protect any transmission line from damage by any trees or undergrowth on any land, including State Land, the operator concerned may, without any notice to the owner or lawful occupier, enter upon such land and cause such trees or undergrowth to be cut down or trimmed in such manner as may be necessary to prevent the damage.

(As amended by Act No. 21 of 2003)

 

 

18.  (1)  Except with the permission of the operator of the undertaking who has control of the transmission line in question, no person shall erect any building or structure in such a position or manner as to be likely to interfere with the supply of electricity through any transmission line.

Obstruction of lines by buildings, etc.

(2)  If, after a transmission line has been constructed, any person erects any building or structure in such a position or in such a manner as to be likely to interfere with the supply of electricity through the transmission line in question, the operator of the undertaking who controls such transmission line may request the person concerned to remove or adjust the building or structure as may be necessary, and if the person concerned fails to comply with the request, the operator may apply to the Minister for an order for the removal or adjustment of the building or structure and, after due inquiry, the Minister may make such order as may be necessary.

(As amended by Act No. 21 of 2003)

 

 

19.  (1)  Where a person who operates an undertaking has acquired the right to place or replace a transmission line across, under, or along any street or has so placed a transmission line in accordance with this Act or any written law, that person may break up any street in respect of which such rights have been acquired and may, from time to time, repair, alter, or remove any such lines.

Breaking up of streets

(2)  Before exercising any power conferred by this section, the operator of an undertaking shall give to the local authority or other authority concerned such notice, in writing, as it may require, not exceeding twenty-eight days, of the operator's intention to do so, except in cases of emergency, when the operator shall give notice thereof to that authority as soon as possible after the emergency has arisen, and shall likewise give notice to the owner of water pipes, telephone cables, or other installations likely to be affected by the exercise of such power.

 

(3)  Except in cases of emergency, the powers conferred by this section shall be exercised under the superintendency of the local or other authority concerned and according to such specifications and such plan showing the route approved by that authority or, if any difference arises respecting the specification, plan or route, then as may be approved by the Minister:

 

Provided that, if the authority concerned fails to exercise the powers of superintendency herein conferred after such notice has been given, the operator may exercise those powers without such superintendency.

 

(4)  Whenever the operator of any undertaking carries out any work authorised under this section, the operator shall comply with the by-laws and regulations of the local or other authority concerned, and shall complete that work with reasonable despatch, and shall reinstate and make good the street opened or broken up and remove the rubbish occasioned thereby, and shall, while the street is opened or broken up or obstructed, cause the works to be at all times fenced and guarded and to be lit during the night.

 

(5)  If the operator of an undertaking fails to carry out any duty imposed by subsection (4), the local or other authority concerned may cause any work delayed or omitted to be executed at the expense of the operator.

 

(6)  The operator of an undertaking shall pay to the local or other authority concerned costs reasonably and necessarily incurred by it in exercising any necessary superintendency under this section, or in reinstating and making good any street opened or broken up by the operator.

(As amended by Act No. 21 of 2003)

 

 

20.    In the exercise of powers in relation to the execution of works given under this Act, an operator of an undertaking shall cause as little detriment and inconvenience and do as little damage as possible, and shall make full compensation to all local and other authorities and other persons who have sustained damage, for all damage sustained by them by reason or consequence of the exercise of such powers and, in default of agreement between the parties, the amount and application of such compensation shall be determined by Arbitration in accordance with the provisions of the Arbitration Act and for that purpose the parties shall be deemed to be parties to a submission in which the reference is to two arbitrators.

Compensation for damage in the exercise of powers
Cap. 41

 

PART IV

OFFENCES AND PENALTIES

 

 

21.  (1)  Any person who, without legal right, abstracts or causes to be abstracted, or diverts or causes to be diverted, any electric current, or consumes or uses any such current, knowing the same to have been wrongfully or unlawfully abstracted or diverted, shall be guilty of an offence.

Interference with supplies and apparatus

(2)  Any person who, without legal right, cuts, injures or interferes with any apparatus for generating, transmitting or distributing or supplying electricity, or maliciously extinguishes or damages any lamp or other electric apparatus provided for the convenience of the public, shall be guilty of an offence.

 

22.    Any person who, in giving information, making any application or claim, or giving any notice for the purpose of any provision of this Act, makes any statement that the person knows to be false in a material particular, shall be guilty of an offence.

False information

23.    Any person who carries on an undertaking in contravention of this Act, or any person who fails to carry out any order or decision of the President, the Minister or the Board under this Act shall be guilty of an offence.

Contraventions of Act

24.    Any person who is guilty of an offence under this Act shall be liable in respect of each offence to a fine not exceeding one hundred thousand penalty units, or to imprisonment for a period not exceeding five years, or to both.

Penalties

 

PART V

GENERAL

 

 

25.    The Board or any person authorised in writing by the Board may, at all reasonable times, enter the premises of any undertaking for the purpose of ascertaining whether the provisions of this Act or the conditions of any licence are being complied with.

(As amended by Act No. 21 of 2003)

Entry and inspection

26.    The operator of an undertaking and any person authorised in writing by the operator may at all reasonable times enter any premises to which electricity is or has been supplied by the operator in order to inspect transmission lines, fittings, meters, and apparatus and for the purpose of ascertaining the quantity of electricity consumed or, where a supply is no longer required or such operator is authorised to cut off the supply from such premises, for the purpose of removing any transmission lines, fittings, meters, and apparatus belonging to such operator and any damage caused by such entry, inspection, or removal shall be repaired and made good by the operator.

Operator's powers of entry and inspection

27.    The Board may, for purposes of this Act, require the operator of an undertaking to provide information relating to the activities and operations of the undertaking, including records, documents and agreements relating to the purchase and sale of electricity as the Board may require.

(As amended by Act No. 21 of 2003)

Information and records

28.  (1)  The operator of an undertaking shall send to the Board notice of any accident of such a kind as to have caused, or to have been likely to have caused, loss of life or serious personal injury which has occurred in any part of such operator's works or transmission lines, together with notice of any loss of life or serious personal injury occasioned by any such accident and any such operator who fails to send such notice as soon as possible after the occurrence of the accident has become known to him shall be guilty of an offence.

Notice of accidents

(2)  Nothing contained in subsection (1) shall absolve the operator of an undertaking from the need to comply with the provisions of any other written law relating to the reporting of accidents.

 

29.    Any notice or other document required or authorised to be given under this Act may be given-

(a)        by delivering it to the person to whom it is directed;

(b)        by leaving it at the usual or last known place of abode of that person;

(c)        by sending it in a prepaid registered letter addressed to that person at the person's usual or last known place of abode, place of business or postal address;

(d)        in the case of a company, by delivering it to the Secretary of the company at its registered or principal office, or by sending it in a prepaid registered letter addressed to the secretary of the company at that office; or

(e)        where-

Serving of notice

(i)         the notice is to be given to a person in the person's capacity as the holder of any interest in land;
and

 

(ii)        it is not practical, after reasonable inquiry, to ascertain the person's name or address;

by addressing the notice to the person having that interest in the premises (specifying the premises and the interest concerned) and by delivering it to some person on the premises, or if there is no person on the premises to whom it can be delivered, by affixing it, or a copy of it, to some conspicuous part of the premises.

 

 

30.  (1)  The Minister may, by statutory instrument, make regulations for the better carrying out of the provisions of this Act.

Regulations

(2)  Without derogating from the generality of subsection (1), regulations may provide for the following matters:

 

(a)        the maintenance of security of supply of electricity within Zambia;

 

(b)        the standards with which buildings, machinery, transmission lines, and other works of whatever description, which are required to generate, transmit, convert, distribute or supply electricity must comply;

 

(c)        the construction, installation, quality, alteration, operation, control, protection and inspection and testing of works, plant, machinery, apparatus, appliances, and equipment for or incidental to the generation, transmission, distribution, connection, installation and use of electricity, whether on the premises of the operator of an undertaking or a consumer;

 

(d)        securing the safety of the public from personal injury or damage to property arising from the generation, transmission, conversion, distribution, supply, or use of electricity;

 

(e)        prescribing anything to be prescribed under this Act.

 

(3)  Regulations made under this Act may provide that persons offending against the regulations shall be liable to a fine not exceeding one hundred thousand penalty units or to imprisonment for a period not exceeding two years, or to both.

 

(4)  In exercise of the power conferred by this section, the Minister may provide for different regulations to apply to different undertakings or consumers or to different classes of undertakings or consumers.

(As amended by Act No. 21 of 2003)

 

31.    The Electricity Act, 1956 is hereby repealed.

 

Repeal of Act No. 8 of 1956

 

SUBSIDIARY LEGISLATION

 

 

ELECTRICITY

 

 

SECTION 38-THE ELECTRICITY (ACQUISITION OF LAND) REGULATIONS

Regulations by the Minister

Federal Government Notices
119 of 1956
Government Notices
34 of 1964
497 of 1964

 

1.    These Regulations may be cited as the Electricity (Acquisition of Land) Regulations.*


*These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    An application for an order of the President for the acquisition of land in accordance with the provisions of section twenty-two of the Act shall be made to the Minister and shall set out-

(a)        full particulars concerning the land which the authorised undertaker wishes to acquire;

(b)        the reasons why the acquisition of the land in question is necessary for the purposes of the undertaking carried on by the authorised undertaker concerned;

(c)        full particulars of the steps taken by the authorised undertaker to acquire the land by agreement with the owner; and

(d)        any other particulars which the Minister may require.

(As amended by G.N. No. 34 of 1964)

Application for order for acquisition of land

 

SECTION 38-THE ELECTRICITY (ANNUAL RETURNS)
REGULATIONS

Regulations by the Minister

Federal Government Notices
120 of 1956
336 of 1962
Government Notice
34 of 1964

 

1.    These Regulations may be cited as the Electricity (Annual Returns) Regulations.*


 *These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"licence" means a licence issued, or deemed to have been issued, in accordance with the provisions of the Act;

 

 

"licensee" means a person to whom a licence has been issued, or has been deemed to have been issued, in accordance with the provisions of the Act;

 

 

"scheduled prices" means a schedule of standard prices contained in a licence.

 

 

3.    Every local authority and licensee shall, within six months of the close of the financial year of his undertaking, submit to the Electricity Council a copy of the audited balance sheet and accounts of his undertaking made up to the end of that financial year, together with any report of the auditor thereon:

Submission of audited accounts to Electricity Council

 

Provided that, if a local authority or a licensee cannot within such period submit a copy of such audited balance sheet on the grounds that his accounts have not by that time been audited, he shall within six months of the end of such financial year submit a copy of his balance sheet and accounts certified by the accountant or treasurer responsible for those accounts and shall thereafter, as soon as they are available, submit copies of such audited accounts to the Electricity Council.

(As amended by G.N. No. 34 of 1964)

 

 

4.    The Electricity Council may at its discretion permit a local authority or licensee to submit the returns required in accordance with the provisions of regulation 3 within a longer period than that laid down in that regulation.

Extension of period

 

5.    Every local authority, licensee and every private undertaker who has contracted to supply electricity to any other person shall, within six months of the close of the financial year of his undertaking, submit to the Electricity Council a return setting out the following information with regard to his undertaking in respect of that financial year:

(a)        the number of units generated;

(b)        the number of consumers of various classes supplied;

(c)        the number of units of electricity sold to each class;

(d)        the prices charged;

(e)        the following particulars relating to consumers who have been supplied with electricity at prices above or below the scheduled prices in accordance with the provisions of section twelve of the Act:

Submission of returns to Electricity Council

 

(i)         the names of the consumers;

 

 

(ii)        the amount of electricity supplied;

 

 

(iii)       the prices charged for electricity;

(f)         such other information as may be required by the Electricity Council.

(As amended by F.G.N. No. 336 of 1962
and G.N. No. 34 of 1964)

 

 

6.    Any person who contravenes or fails to comply with any provision of these Regulations with which it is his duty to comply shall be guilty of an offence and liable to a fine not exceeding one thousand five hundred penalty units.

(As amended by Act No. 13 of 1994)

Offences and penalties

 

SECTION 38-THE ELECTRICITY AUTHORITY (MEMBERSHIP AND PROCEEDINGS) REGULATIONS

Regulations by the Minister

Federal Government Notice
116 of 1956
Government Notice
34 of 1964
Statutory Instrument
157 of 1965

 

1.    These Regulations may be cited as the Electricity Authority (Membership and Proceedings) Regulations.*


 *These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"authority" means the Electricity Council.

(As amended by G.N. No. 34 of 1964)

 

 

3.    These Regulations shall apply to all members of the authority appointed, or deemed to have been appointed, under the provisions of the Act.

(As amended by G.N. No. 34 of 1964 and S.I. No. 157 of 1965)

Application

 

4.  (1)  Notwithstanding the conditions of his appointment, a member of the authority shall cease to be a member-

(a)        on conviction under the provisions of the Act;

(b)        on conviction by any court accompanied by sentence of imprisonment without the option of a fine;

(c)        on being declared bankrupt;

(d)        on being absent without the approval of the chairman of the authority from four consecutive meetings of the authority; or

(e)        when, in the opinion of the Minister, he is prevented by disability of body or mind from properly performing his functions as a member.

Tenure of office

 

(2)  A member of the authority who wishes to resign his membership shall give written intimation to the Minister of his wish to resign, and his resignation shall become effective only upon its acceptance by the Minister.

(As amended by G.N. No. 34 of 1964 and S.I. No. 157 of 1965)

 

 

5.    If a member of the authority has any direct interest, whether pecuniary or otherwise, in any business connected with the generation supply, purchase or sale of electricity or electrical appliances. he shall, at the time of his appointment as such member, disclose in writing to the Minister the fact and nature of his interest and shall make a similar disclosure from time to time of any acquisition of or any change in such interest and, unless the Minister otherwise directs, shall take no part in any deliberation or decision of the authority which relates to any such business.

(As amended by S.I. No. 157 of 1965)

Member to declare interest

 

6.    No meeting of the authority shall be open to the press or to the public unless the authority shall otherwise decide in respect of any particular meeting or part thereof.

Publicity

 

7.    The authority shall normally meet on occasions decided by its chairman and, whenever the Minister, the chairman or not less than half of the appointed members of the authority require a meeting, the secretary of the authority shall, on being duly instructed, summon a meeting of the authority in such a manner that its members shall in normal circumstances receive notification of the meeting at least fortyeight hours before the time of the meeting.

(As amended by S.I. No. 157 of 1965)

Holding of meetings

 

8.  (1)  At every meeting of the authority, the chairman appointed by the Minister shall, if present at the meeting, be chairman of the meeting. If the chairman appointed by the Minister is absent from the meeting, a member appointed by the Minister to act as chairman or, failing such appointment by the Minister, elected by members present at the meeting, shall act as chairman.

Procedure at meetings

 

(2)  All acts, matters or things authorised or required to be done by the authority shall be decided by resolution of a meeting at which a quorum is present.

 

 

(3)  Every question for decision by the authority shall be decided by a majority of votes and, subject to the provisions of regulation 5, each member present at a meeting shall record his vote.

 

 

(4)  If at any meeting of the authority the voting is equal on any matter for decision by the authority, the chairman or member acting as such shall have a casting vote in addition to his deliberative vote.

 

 

(5)  Not less than half the members of the authority shall constitute a quorum of any meeting of the authority.

 

 

(6)  The chairman or member acting as such shall declare the result of any decision of the authority and such declaration shall be final.

(As amended by S.I. No. 157 of 1965)

 

 

9.  (1)  Minutes shall be kept of the proceedings of every meeting of the authority. The minutes of the proceedings of a meeting of the authority shall be submitted at the next ensuing meeting and, if they are passed as correct. shall be signed by the chairman or the member acting as such. and the signed record of the proceedings of a meeting shall be prima facie evidence in all courts and circumstances that the proceedings as recorded were the proceedings of the meeting. Within fourteen days of their being signed, the chairman of the authority shall cause two copies of the signed minutes of each meeting to be sent to the Minister.

Minutes of meetings

 

(2)  Any member of the authority who has recorded a minority vote may have it recorded in the minutes that he dissented from any resolution and also, briefly, his reasons for such dissent.

 

 

(3)  No motion or discussion shall be allowed on the minutes except as to their accuracy.

(As amended by S.I. No. 157 of 1965)

 

 

SECTION 38-THE ELECTRICITY (INQUIRIES INTO ACCIDENTS) REGULATIONS

Regulations by the Minister

Federal Government Notice
109 of 1957
Government Notices
34 of 1964
497 of 1964
Statutory Instrument
157 of 1965
Act
13 of 1994

 

1.    These Regulations may be cited as the Electricity (Inquiries into Accidents) Regulations.*


 *These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"assessor" means an assessor appointed in terms of regulation 3 (3);

 

 

"board" means a board of inquiry appointed in terms of regulation 3 (1).

 

 

3.  (1)  Whenever, in accordance with the provisions of section thirtyfive of the Act, the Minister has ordered an inquiry to be held into the circumstances of an accident of which notice has been sent to him in terms of section thirtysix of the Act, he may appoint a board of inquiry which he may direct to answer such specific or general questions in relation to the accident as he may think proper in the public interest.

Appointment of boards of inquiry

 

(2)  A board shall consist of such members as the Minister may appoint and, if it consists of more than one member, the Minister shall nominate one of the members as the chairman of the board.

 

 

(3)  To assist a board, the Minister may appoint one or more assessors possessing special skill or knowledge relating to the questions to be investigated by the board.

 

 

(4)  If any member of a board is, or becomes, unable or unwilling to act, or dies, the Minister may appoint another member in his place and, if such firstmentioned member was chairman, may nominate another member of the board as chairman.

 

 

4.    A board shall sit at such times and at such places as it may fix and shall hold its inquiry in public except in so far as it is of the opinion that it is necessary, for any of the reasons set out in Article 18 (II) of the Constitution, that any part of the evidence given before it and any argument relating thereto should be heard in camera.

(As amended by S.I. No. 157 of 1965)

Sittings and procedure
Cap. 1

 

5.    If the members of a board are in a any case equally divided on any question that arises during the proceedings of the board, the chairman of the board shall have a second or casting vote.

Chairman to have casting vote

 

6.    A board shall have power to inspect, or authorise any person to inspect, any electrical installations concerned in an accident which is the subject of its inquiry and to enter and inspect any premises of any undertaking, including any generating station or transmission line, where the entry and inspection thereof appears to the board to be necessary for the purpose of its inquiry.

Rights of entry and inspection

 

7.    If any person at any sitting of the board wilfully insults any member of the board or any assessor or wilfully interrupts the proceedings of the board or otherwise wilfully disturbs the peace or order of such proceedings, he shall be guilty of an offence and liable to a fine not exceeding one thousand five hundred penalty units or, in default of payment, to imprisonment for a period not exceeding six months.

(As amended by Act No. 13 of 1994)

Offences and penalties

 

8.    Any person who is in any way implicated or concerned in the matter under inquiry by a board shall be entitled to be represented by a legal practitioner at the whole of the inquiry, and any other person who may consider it desirable that he should be so represented may, by leave of the board, be represented in the manner aforesaid.

Legal representation

 

9.  (1)  The Minister may direct what remuneration, if any, shall be paid to the members of a board and any assessor and may direct the payment of any other expenses attendant upon the carrying out of the board's functions.

Remuneration of members

 

(2)  Any sums payable in terms of this regulation shall be paid out of moneys appropriated for the purpose by Parliament.

(As amended by G.N. No. 34 of 1964)

 

 

SECTION 38-THE ELECTRICITY (INQUIRIES INTO DISPUTES PROCEDURE) REGULATIONS

Regulations by the Minister

 

Federal Government Notice
141 of 1962
Government Notices
34 of 1964
497 of 1964
Statutory Instrument
157 of 1965
Act
13 of 1994

 

1.    These Regulations may be cited as the Electricity (Inquiries into Disputes Procedure) Regulations.*


 *These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"board" means a board of inquiry appointed in terms of regulation 5;

 

 

"dispute" means a difference referred to in regulation 5 (2) of the Supply Regulations or in regulation 5 of the Wiring Regulations;

 

 

"inspector" means a person appointed in terms of regulation 5 for the purpose of inquiring into and determining a dispute;

 

 

"Supply Regulations" means the Electricity (Supply) Regulations;

 

 

"Wiring Regulations" means the Electricity (Wiring) Regulations.

 

 

3.    Whenever in accordance with the provisions of section thirty five of the Act the Minister directs an inquiry to be held into a dispute, such inquiry shall be conducted in accordance with the provisions of these Regulations.

Conduct of inquiry

 

4.    An application for an inquiry shall-

(a)        be made to the Minister in writing by one of the parties to the dispute; and

(b)        contain full details of the dispute which has arisen.

Application for inquiry

 

5.  (1)  If, after considering an application referred to in regulation 4, the Minister is of opinion that the dispute should be inquired into and determined, the Minister shall appoint-

(a)        a person who is an electrical inspector as defined in the Supply Regulations; or

(b)        a board;

Appointment of inspector of board of inquiry

 

for the purpose of inquiring into and determining such dispute and the inspector or the board shall make such order determining the dispute as such inspector or board shall think fit.

 

 

(2)  Subject to the provisions of sub-regulation (3), an order made by an inspector or a board in terms of sub-regulation (1) shall be final and binding on the parties to a dispute.

 

 

(3)  Any party to a dispute who is dissatisfied with an order made in terms of sub-regulation (1) may, within twentyeight days from the making of such order, appeal to the Minister against such order and shall state in detail the grounds of his appeal.

 

 

(4)  The Minister shall consider the appeal and all relevant circumstances relating thereto and shall make such order as he shall think fit which shall be final and binding on the parties to a dispute.

 

 

6.  (1)  An inspector or the members of a board and any assessors appointed to assist a board may enter premises owned or occupied by any party to a dispute and thereon inspect and test electrical works, installations and meters concerned in a dispute.

Rights of entry and inspection

 

(2)  An undertaker involved in a dispute shall-

(a)        permit an inspector or the members of a board to use any testing equipment of his undertaking for the purpose of examining or testing any instrument or thing concerned in the dispute; and

(b)        produce to an inspector or the members of a board for examination all records, books and documents relating to a dispute.

 

 

7.  (1)  A board shall consist of not less than two or more than five members. The Minister shall nominate one of the members as chairman of the board and shall fix the number of members necessary to form a quorum at a meeting of the board.

Membership

 

(2)  To assist a board the Minister may appoint one or more assessors possessing special skill and knowledge relating to the matters to be investigated by the board.

 

 

(3)  If any member of a board is, or becomes, unable or unwilling to act, or dies, the Minister may appoint another member in his place and, if such firstmentioned member was chairman, may nominate another member of the board as chairman.

 

 

8.    A board shall sit at such times and at such places as it may fix and shall hold its inquiry in public except in so far as it is of the opinion that it is necessary, for any of the reasons set out in Article 18 (eleven) of the Constitution, that any part of the evidence given before it and any argument relating thereto should be heard in camera.

(As amended by S.I. No. 157 of 1965)

Sittings and procedure
Cap. 1

 

9.    If the members of a board are in any case equally divided on any question that arises during the proceedings of the board, the chairman of the board shall have a second or casting vote.

Chairman to have casting vote

 

10.    If any person at any sitting of the board wilfully insults any member of the board or any assessor or wilfully interrupts the proceedings of the board or otherwise wilfully disturbs the peace or order of such proceedings, he shall be guilty of an offence and liable to a fine not exceeding one thousand five hundred penalty units or, in default of payment, to imprisonment for a period not exceeding six months.

(As amended by Act No. 13 of 1994)

Offences and penalties

 

11.    Any party to a dispute which is being investigated by a board shall be entitled to be represented by a legal practitioner at the whole of the inquiry, and any other person who may consider it desirable that he should be so represented may, by leave of the board, be represented in the aforesaid manner.

Legal representation

 

12.  (1)  The Minister may direct what remuneration, if any, shall be paid to the members of a board and any assessor and may direct the payment of any other expenses attendant upon the carrying out of the board's functions.

Remuneration of members

 

(2)  Any sums payable in terms of this regulation shall be paid out of moneys appropriated for the purpose by Parliament.

(As amended by G.N. No. 34 of 1964)

 

 

SECTION 38-THE ELECTRICITY (LICENSING) REGULATIONS

Regulations by the Minister

Federal Government Notice
117 of 1956
Government Notice
34 of 1964
Statutory Instrument
157 of 1965
Act
13 of 1994

 

1.    These Regulations may be cited as the Electricity (Licensing) Regulations.*


 *These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2)

Title

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"applicant" means a person who has applied or is applying, in accordance with the provisions of the Act, for the issue or review of a licence, or an amended licence, or for the cession, transfer, surrender or substitution of a licence;

 

 

"licensee" means a person to whom a licence has been issued, or has been deemed to have been issued, in accordance with the provisions of the Act.

 

 

3.    An application for a licence in terms of section seven of the Act, an application for the review of a licence in terms of paragraph (a), (b) or (c) of subsection (1) of section nine of the Act, and an application for the cession, transfer, surrender or substitution of a licence in terms of subsection (2) of section nine of the Act may be made at any time and shall be addressed to the Secretary of the Electricity Council.

(As amended by G.N. No. 34 of 1964)

Applications for licences

 

4.  (1)  An application made in terms of section seven of the Act or of paragraph (c) of subsection (1) of section nine of the Act or of subsection (2) of section nine of the Act shall be in Form 1 in the First Schedule and shall be accompanied by the appropriate fee as set out in the Second Schedule, and by a plan of the area of supply, and by particulars concerning the following matters where applicable:

(a)        the situation and extent of the land which the applicant desires to use as sites for generating stations;

(b)        if the ownership of the site is not vested in the applicant, the name and address of the owner;

(c)        the source of the water supply and the usual quantity used or required:

(d)        full particulars of land or any rights over land which it is proposed to acquire either by agreement or in accordance with the provisions of the Act;

(e)        full particulars regarding the type of current, frequency and pressure to be used.

(f)         full particulars of the proposed undertaking, including the maximum quantity of electricity which will normally be generated and the maximum installed capacity of the plant;

(g)        the estimated cost of the undertaking;

(h)        the point or points at which it is proposed to receive any supply of electricity in bulk;

(i)         a schedule of charges; to be made to consumers;

(j)         an estimate of the number of probable consumers within the area of supply and their estimated consumption of electricity;

(k)        such further particulars and information as may be required by the Electricity Council or the Minister.

Fees and particulars required

 

(2)  In addition to the information required under sub-regulation (1), an applicant shall submit to the Electricity Council a draft advertisement containing the following particulars where appropriate:

(a)        the description and address of the applicant;

(b)        the object of the application;

(c)        the proposed area of supply;

(d)        the site and capacity of the proposed generating station;

(e)        any further particulars which the Electricity Council may require to be included;

(f)         a statement to the effect that plans and documents of the applicant's proposals, together with details of the tariffs which it proposes to charge, are available for view by the public at a suitable and convenient place within the area of supply;

(g)        a statement to the effect that any consumer or proposed consumer within the area covered by the application may object to the approval of the application in accordance with the provisions of regulation 6.

 

 

(3)  An applicant who wishes to include in his area of supply all or part of the area under the jurisdiction of a local authority shall attach to his application a consent of such local authority or a decision of the Minister, as the case may be, given or made in terms of section nineteen of the Act.

(As amended by G.N. No. 34 of 1964)

 

 

5.    On receipt of an application made in terms of regulation 4, the Electricity Council shall, if satisfied that the applicant has complied with the provisions of the Act and of these Regulations and that the draft advertisement contains the necessary particulars, cause the advertisement to be inserted at the applicant's expense in the Gazette and in a newspaper circulating in the proposed area of supply.

(As amended by G.N. No. 34 of 1964)

Advertisement of application

 

6.    Any objection to the grant of an application which has been made in terms of regulation 4 shall be made in Form 2 in the First Schedule and shall be lodged with the Electricity Council within twentyone days of the appearance in the Gazette of the relevant advertisement published in terms of regulation 5. Any objection made against the granting of an application shall contain the reasons for the objection and copies of any objections so made shall be lodged with the applicant.

(As amended by G.N. No. 34 of 1964)

Notice of objection to grant of application

 

7.    The Electricity Council shall arrange for the hearing of an application made in terms of regulation 4, and any objection thereto made in terms of regulation 6, at a suitable time and place and shall give notice of such hearing to the applicant and to every objector not less than ten days before the date fixed for the hearing:

Hearing of application

 

Provided that, if there are more than twenty objectors to any one application, the Electricity Council may, by advertisement in a newspaper circulating in the area of supply covered by the application, give notice of the hearing of the application and objections thereto, and the appearance of such advertisement shall be regarded as the giving of notice to every objector in terms of this regulation

(As amended by G.N. No. 34 of 1964)

 

 

8.    When the Electricity Council has heard an application made in terms of regulation 4 and any objections thereto, it shall make its recommendations to the Minister on the application in accordance with the provisions of the Act, and its recommendations shall include the terms and conditions which should be described in the licence.

Electricity Council to make recommendations to Minister

 

9.    If a number of consumers or a local authority wish the Minister to review a licence in terms of paragraph (a) or (b) of subsection (1) of section nine of the Act, they shall make application to the Electricity Council for the issue by the Minister of an amended licence to the licensee concerned and shall send a copy of such application to such licensee. An application made in terms of this regulation shall be in Form 3 in the First Schedule.

(As amended by G.N. No. 34 of 1964)

Application for review of licence

 

10.  (1)  A number of consumers seeking the review of a licence in terms of regulation 9 shall, at the time of making application, satisfy the Electricity Council that they represent the aggregate consumption required by paragraph (a) of subsection (1) of section nine of the Act, and the Electricity Council shall not consider any such application unless so satisfied.

Consumers to represent requisite consumption

 

(2)  A licensee shall give to consumers who wish to seek the review of his licence in terms of regulation 9 such information as may be necessary for those consumers to satisfy the Electricity Council in accordance with the provisions of sub-regulation (1).

(As amended by G.N. No. 34 of 1964)

 

 

11.    An application made in terms of regulation 9 shall contain the following information:

(a)        details of the amendments to the licence which the applicants seek;

(b)        the reasons for seeking the amendments;

(c)        any other information which may be required by the Electricity Council.

(As amended by G.N. No. 34 of 1964)

Particulars required

 

12.    On receipt of an application made in terms of regulation 9, the Electricity Council shall arrange for the hearing of the application at a suitable time and place and shall give an opportunity to representatives of the licensee and of any other applicant concerned to appear and to lead evidence in accordance with the provisions of subsection (4) of section nine of the Act.

(As amended by G.N. No. 34 of 1964)

Hearing of application

 

13.    Having heard the application made in terms of regulation 9, the Electricity Council shall make its recommendations to the Minister as to the provisions and conditions to be included in the licence.

(As amended by G.N. No. 34 of 1964)

Electricity Council to make recommendations to Minister

 

14.    If the Electricity Council proposes to recommend in terms of paragraph (d) of subsection (1) of section nine of the Act that the Minister shall review a licence, it shall notify the licensee in writing of the alterations in the licence which it proposes to recommend.

Notification of licensee

 

15.    On receipt of a recommendation from the Electricity Council made in terms of paragraph (d) of subsection (1) of section nine of the Act, the Minister shall insert in the Gazette and in a newspaper circulating in the licensed area an advertisement setting out the changes proposed in the licence, which shall include a statement to the effect that the licensee or any consumer or proposed consumer in the licensed area may lodge his objection with the Minister.

(As amended by G.N. No. 34 of 1964)

Advertisement of proposed changes in licence

 

16.    Any objection made in terms of regulation 15 against the approval by the Minister of a recommendation received from the Electricity Council in terms of paragraph (d) of subsection (1) of section nine of the Act shall be made in Form 2 in the First Schedule and shall be lodged with the Minister within twentyone days of the appearance in the Gazette of the relevant advertisement published in terms of regulation 15. Any objection made against the approval of such a recommendation shall contain the reasons for the objections and copies of any objections so made shall be lodged with the Electricity Council and with the licensee.

(As amended by G.N No. 34 of 1964 and S.I. No. 157 of 1965)

Notice of objection

 

17.    Before making a decision on any recommendation of the Electricity Council made in terms of paragraph (d) of subsection (1) of section nine of the Act, the Minister shall, if so requested by any objector or by the Electricity Council, arrange for a hearing of the recommendation to be conducted, mutatis mutandis, in accordance with the provisions of regulation 12

(As amended by G.N. No. 34 of 1964)

Hearing

 

18.  (1)  An application made in terms of these Regulations shall be accompanied by the appropriate fees set out in the Second Schedule. If by any reason of inquiries into the affairs of the licensee additional expense is necessarily incurred by the Minister or the Electricity Council as the result of an application made in terms of these Regulations, the Minister may direct that all or part of the additional expense so incurred shall be paid by the applicant, so, however, that in the case of an application made in terms of paragraph (a) or (b) of subsection (1) of section nine of the Act, no additional expenses shall be payable by the applicant if as the result of that application an amendment to the licence is made.

Fees

 

(2)  The issue of a licence or of an amended licence, as the case may be, shall be conditional upon the payment of such amounts as may be payable by the applicant in terms of this regulation .

 

 

FIRST SCHEDULE
 

PRESCRIBED FORMS

 

 

 


 

FORM 1
(Regulation 4)

APPLICATION FOR THE ISSUE OF A LICENCE OR OF AN AMENDED LICENCE

 

 

To the Secretary,
Electricity Council.

    Application is hereby made under the provisions of the Electricity Act-

*for the issue of a licence

*for the issue of an amended licence

*for the cession/transfer/surrender/substitution of a licence in the following manner:         

           

    Attached hereto are the fees and statements of information and particulars as required in terms of the Regulations.

    Dated this                                                                                 day of                                                                  19          .

Signature of Applicant           

Address          

    *Insert as appropriate.

(As amended by S.I. No. 157 of 1965)

 

 


 

FORM 2
(Regulations 6 and 16)

NOTICE OF OBJECTION TO THE ISSUE OF A LICENCE OR OF AN
AMENDED LICENCE

 

 

To the Secretary,
*Electricity Council.
*The Permanent Secretary, Ministry of Power, Transport and Works.
    Objection is hereby made to-
*the issue of a licence
*the issue of an amended licence.

*the cession/transfer/surrender/substitution of a licence in respect of the     

             undertaking in the

terms contained in Gazette Notice No.                                                  of                                                               19          .

The grounds for objection are            

           

           

Dated this                                                                                        day of                                                               19          .

Signature of objector

Address          

    *Insert as appropriate.

(As amended by S.I. No. 157 of 1965)

 

 


 

FORM 3
(Regulation 9)

APPLICATION FOR THE REVIEW OF A LICENCE

 

 

To the Secretary,
Electricity Council.

    Application is hereby made to the Minister of Power, Transport and Works under the provisions of the Electricity Act, for the review of the licence issued to        undertaking. Attached
hereto are statements setting out details of the amendments to the licence for which application is made, and setting out the reasons for seeking those amendements. Also attached are the fees payable with this application in terms of the Regulations.

    Dated this                                                                           day of                                                                       19          .

Signature of Applicants                                                              Addresses

                        ............................................................    ............................................................

                        ............................................................    ............................................................

                        ............................................................    ............................................................

(As amended by S.I. No. 157 of 1965)

 

 


 

SECOND SCHEDULE

(Regulation 18)

 

 

 

FEES TO ACCOMPANY APPLICATIONS IN CONNECTION WITH LICENCES

Fee units

With an application for the issue of a licence in accordance with the
provisions of section 7 of the Act       . .         . .         . .         . .         . .         . .      1500

With an application for the review of a licence in accordance with
the provisions of paragraph (a) of subsection (1) of section 9 of
the Act                                                . .         . .         . .         . .         . .         . .        300

With an application for the review of a licence in accordance with
the provisions of paragraph (b) of subsection (1) of section 9 of
the Act                                                . .         . .         . .         . .         . .         . .        600

With an application for the review of a licence in accordance with the
provisions of paragraph (c) of subsection (1) of section 9 of the Act            . .              . .     . .                                                              400

With an application for the cession or transfer of a licence in accor-
dance with the provisions of subsection (2) of section 9 of the Act . .         . .              . .       750

With an application for the substitution of a licence in accordance
with the provisions of subsection (2) of section 9 of the Act. .         . .         . .              . .       150

With an applicaton for the surrender of a licence in accordance
with the provisions of subsection (2) of section 9 of the Act. .         . .         . .              . .         Nil

(As amended by Act No. 13 of 1994)

 

 

SECTION 38-THE ELECTRICITY (NON-STANDARD CHARGES) REGULATIONS

Regulations by the Minister

Federal Government Notice
312 of 1959
Government Notice
34 of 1964

 

1.    These Regulations may be cited as the Electricity (Non-Standard Charges) Regulations.*


*These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"applicant" means a consumer referred to in subsection (4) of section twelve of the Act, and "application" shall be construed accordingly;

 

 

"the right to appear and lead evidence" means the right to appear and lead evidence conferred by the provisions of subsection (6) of section twelve of the Act.

(As amended by G.N. No. 34 of 1964)

 

 

3.  (1)  An application shall be in writing.

Particulars required

 

(2)  In an application the applicant shall state-

(a)        the reasons for his application; and

(b)        whether or not he wishes to exercise the right to appear and lead evidence.

 

 

4.    The applicant shall submit his application to the Electricity Council forwarding at the same time a copy of his application to the licensee.

(As amended by G.N. No. 34 of 1964)

Submission of application

 

5.  (1)  If the licensee wishes to object to the application, he shall lodge a notice of his objection in writing with the Electricity Council within thirty days of the receipt by him of the copy of the application forwarding at the same time a copy of his objection to the applicant.

Notice of objection

 

(2)  A licensee who lodges a notice of objection referred to in sub-regulation (1) (hereinafter called an objector) shall state in the objection whether or not he wishes to exercise the right to appear and lead evidence.

 

 

6.  (1)  The Electricity Council may require an applicant or licensee, whether or not he is an objector, to furnish such information which in its opinion is relevant to the application and any objection thereto as it may consider necessary for the proper consideration of the application and any objection thereto.

Particulars of objection required

 

(2)  The applicant and the licensee shall furnish such information as they may be required to furnish in terms of sub-regulation (1).

 

 

(3)  The Electricity Council shall furnish the objector with copies of information obtained from the applicant and the applicant with copies of information obtained from the objector.

 

 

7.    In addition to the power to require an applicant or licensee to furnish information conferred upon it by regulation 6, the Electricity Council may institute such inquiries and obtain such other information which in its opinion is relevant to the application and any objection thereto as it may consider necessary for the proper consideration of the application and any objection thereto.

Further inquiries

 

8.    If an applicant or an objector wishes to exercise the right to appear and lead evidence, the Electricity Council shall arrange a suitable time and place for that purpose and give notice to him and the other party, if any, not less than ten days before the date so arranged.

 

Right to appear and lead evidence

 

SECTION 38-THE ELECTRICITY (PRIVATE UNDERTAKINGS' CONTRACTS) REGULATIONS

Regulations by the Minister

Federal Government Notice
122 of 1956
Government Notice
34 of 1964
Act
13 of 1994

 

1.    These Regulations may be cited as the Electricity (Private Undertakings' Contracts) Regulations.*


 *These Regulation made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    Any person operating a private undertaking who, in accordance with the provisions of section eighteen as read with subsection (3) of section thirtynine of the Act, requires the consent of the Minister before contracting to supply electricity to any other person shall submit his application for the Minister's consent to the Electricity Council.

(As amended by G.N. No. 34 of 1964)

Submission of application

 

3.    Every application submitted to the Electricity Council in terms of regulation 2 shall include the following information:

(a)        the type, pressure and quantity of current to be supplied to any other person under the proposed contract;

(b)        the name and address of any person to whom it is proposed to supply electricity under the proposed contract;

(c)        the price to be charged under the proposed contract;

(d)        the provisions to be included in the proposed contract which relate to the termination of the agreement;

(e)        a copy of the proposed contract; and

(f)         any other information which the Electricity Council may require.

(As amended by G.N. No. 34 of 1964)

Particulars required

 

4.    Having considered the application, the Electricity Council shall submit to the Minister full details of the application and its recommendation thereon.

Recommendation of Electricity Council

 

5.    The Minister shall thereupon notify his decision to the private undertaker and, if the Minister gives his consent in terms of section eighteen of the Act, the private undertaker shall lodge with the Electricity Council a copy of the signed contract.

(As amended by G.N. No. 34 of 1964)

Minister's decision

 

6.    The terms of a contract to which consent has been given by the Minister in terms of section eighteen of the Act shall not be varied by a private undertaker without the consent of the Minister. If a private undertaker wishes to obtain the consent of the Minister to a variation of contract already approved by him, he shall submit an application in accordance with the provisions of regulation 3 and thereafter the Electricity Council and the Minister, respectively, shall deal with such application in accordance with the provisions of regulations 4 and 5.

(As amended by G.N. No. 34 of 1964)

Variation of contract

 

SECTION 38-THE ELECTRICITY (REGISTRATION OF PRIVATE UNDERTAKINGS) REGULATIONS

Regulations by the Minister

Federal Government Notice
123 of 1956

 

1    These Regulations may be cited as the Electricity (Registration of Private Undertakings) Regulations.*

 *These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title

 

2.    Every person who, on the 27th April, 1956, operated a private undertaking the plant of which is rated at the site where it is installed at a capacity of one hundred or more kilowatts, whether for his own use or for supply to other persons, either wholly or partly, shall before the 1st October, 1956, submit to the Minister the following particulars in respect of the plant and installation:

(a)        the name and address of the owner;

(b)        the place where it is operated;

(c)        the rated capacity, type of prime mover and current, systems, frequency and voltage; and

(d)        any further relevant particulars required by the Minister.

Particulars required in respect of existing undertakings

 

3.    Every person who, after the 27th April, 1956, begins to operate a private undertaking as described in regulation 2 shall, within six months after so beginning to operate it, submit to the Minister the particulars set out in that regulation in respect of the plant and installation in question.

Particulars required in respect of new undertakings

 

4.    Any person who fails to comply with the provisions of these Regulations shall be guilty of an offence and shall be liable to a fine not exceeding seven hundred and fifty penalty units.

(As amended by Act No. 13 of 1994)

Offences and penalties

 

THE ELECTRICITY (SUPPLY) REGULATIONS

 

 

ARRANGEMENT OF REGULATIONS

 

 

PART I

PRELIMINARY

 

 

Regulation

  1.          Title and commencement

  2.          Interpretation

 

 

PART II

ADMINISTRATION AND GENERAL

 

 

  3.          Chief Electrical Inspector and electrical inspectors

  4.          Application

  5.          Procedure as to settlement of disputes

  6.          Declared method of supply to new consumers

  7.          Declared method of supply to existing consumers

  8.          Undertaker to provide constant supply

  9.          Undertaker may lessen or discontinue supply

10.          Undertaker shall not permanently connect

11.          Undertaker not compelled to commence supply

12.          Discontinuance of supply

13.          Disconnection of works in certain circumstances

14.          Connection of system with earth

15.          Protection of telegraphs

16.          Access to undertaker's works

17.          Guidance and instructions

18.          Inspections and tests

19.          Availability of Regulations

 

 

PART III

CONSTRUCTION OF UNDERTAKERS' WORKS

 

 

20.          Design and protection of works

21.          Switchgear

22.          Fuses

23.          Automatic circuit-breakers

Regulation

24.          Joints and connections

25.          Isolating and protective devices

26.          Switchboards

27.          Buildings for electrical purposes

28.          Outdoor substations

29.          Earthing of metal-work

30.          Earthing of consumer's installation

31.          Earth electrodes

32.          Leakage to earth

33.          Arc suppression coils

34.          Service lines on consumer's premises

 

 

PART IV

CABLES

 

 

35.          Construction and installation of cables

36.          Metallic protection for high-voltage cables

37.          Identification and testing

 

 

PART V

OVERHEAD LINES

 

 

38.          Application of Part V

39.          Constructional requirements

40.          Materials

41.          Minimum heights and clearances

42.          Overhead lines crossing railway tracks

43.          Different voltages in proximity

44.          Loading conditions and factors of safety

45.          Periodic testing and inspecting

46.          Warning notices

47.          Unauthorised climbing

 

 

PART VI

PROTECTIVE MULTIPLE EARTHING

 

 

Regulation

48.          Description

49.          Consent

50.          Limitations

51.          Connections at transformer

52.          Use of cables

53.          Use of overhead lines

54.          Use of cables and overhead lines

55.          Overall resistance

56.          Neutral to be unbroken

57.          Consumer's earthing

 

 

PART VII

STANDARDS OF MEASUREMENT

 

 

58.          Fundamental electrical units

59.          Derived electrical units of energy

60.          Measurement of electricity

 

 

PART VIII

OFFENCES AND PENALTIES

 

 

61.          Offences and penalties

FIRST SCHEDULE-Prescribed forms

SECOND SCHEDULE-Section clearances

THIRD SCHEDULE-Minimum heights of overhead lines

FOURTH SCHEDULE-Minimum heights of overhead lines crossing railway tracks

FIFTH SCHEDULE:             Part I-Fundamental units

                                    Part II-Denominations of standards

                                    Part III-Limits of accuracy

                                    Part IV-Derived electrical unit of energy

 

 

 

SECTION 38-THE ELECTRICITY (SUPPLY) REGULATIONS

Regulations by the Minister 

Federal Government Notice
404 of 1961
Government Notice
34 of 1964
Statutory Instrument
157 of 1965
Act
13 of 1994

 

PART I

PRELIMINARY

 

 

1.    These Regulations may be cited as the Electricity (Supply) Regulations* and shall be deemed to have come into operation-


*These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

(a)        in respect of Parts I, II, IV, V, VI, VII and VIII on the 1st December, 1961;

(b)        in respect of Part III on the 1st January, 1963.

Title and commencement

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"bulk supply" means a supply of electricity to be used for the purposes of redistribution;

 

 

"cable" means an insulated conductor or an assemblage of such conductors enclosed within a common sheathing;

 

 

"conductor" means a bar, tube, wire or line used for conducting electricity;

 

 

"consumer" means a person, other than an undertaker, who is supplied or who has made application to be supplied with electricity by an undertaker;

 

 

"consumer's installation" means the consumer's electrical wiring together with any electricity consuming device connected with such installation;

 

 

"dead" means at or about earth potential or zero voltage and not connected to a live conductor or live part of a system;

 

 

"earthed" and "connected with earth" mean connected with the general mass of earth in such manner as will ensure at all times an immediate and efficient discharge of electricity, and cognate expressions shall be construed accordingly;

 

 

"electric line" means a cable, overhead line or other means used or intended to be used for the purpose of conveying, transmitting or distributing electricity together with any casing, coating, covering, tube, pipe or insulator enclosing, surrounding or supporting the same, or any part thereof, or any apparatus connected therewith for the purpose of conveying, transmitting or distributing electricity;

 

 

"electrical inspector" means a person referred to in regulation 3;

 

 

"failing load" means a load on a support which, if exceeded, will result in the conductor not being supported in accordance with these Regulations;

 

 

"form" means the appropriate form prescribed in the First Schedule;

 

 

"high voltage" means normal operating voltage exceeding 650 volts;

 

 

"insulated conductor" means a conductor covered with insulation suitable for the normal operating voltage;

 

 

"insulation" means non-conducting material enclosing, surrounding, or supporting a conductor or any part thereof;

 

 

"line conductor" means a conductor of an overhead line;

 

 

"Lines Protection Regulations" means the General Post Office (Lines Protection) Regulations;

Cap. 795 of the 1971 edition of the laws

 

"live" means electrically charged;

 

 

"low voltage" means normal operating voltage exceeding 30 volts alternating current or 50 volts direct current but not exceeding 250 volts;

 

 

"main" means an electric line through which electricity may be supplied or is intended to be supplied by the undertaker to a service line;

 

 

"medium voltage" means normal operating voltage exceeding 250 volts but not exceeding 650 volts;

 

 

"metal armouring" means metal wire or metal tape completely covering a cable and manufactured as an integral part of the cable;

 

 

"metal sheathing" means a continuous and watertight metal sleeve surrounding a cable manufactured as an integral part of the cable;

 

 

"metal-work" means any metal-work other than-

 

 

(a)        a conductor and its associated live parts; or

 

 

(b)        an earth conductor;

 

 

"overhead line" means a conductor erected above ground and in the open air and includes any pole-mounted substation associated therewith;

 

 

"pole-mounted substation" means transformer equipment, high-voltage switchgear or high-voltage apparatus mounted on a support and associated with the operation and control of an overhead line;

 

 

"service line" means an electric line through which electricity may be supplied or is intended to be supplied by the undertaker to a consumer either from a main or directly from the premises of the undertaker;

 

 

"supply terminals" means the end of a service line at which the supply of electricity is delivered from such line to the consumer;

 

 

"support" means a structure or pole for supporting an overhead line and includes any stay or strut associated therewith;

 

 

"telegraph" or "telegraph line" means a telegraph or telegraph line as defined in section two of the Posts and Telegraphs Act;

Cap. 795 of the 1971 edition of the laws

 

"undertaker" does not include a person operating a plant which is rated at the site where it is installed at a capacity of less than one hundred kilowatts for the generation and supply of electricity solely for his own use or for use on his own premises;

 

 

"voltage" means the electro-motive force existing between any pair of live conductors forming part of a common supply of electricity or between any part of either of such conductors and earth and, in the case of alternating current, means the virtual voltage or root-mean-square value as determined by the square-root of the mean or average value of the squares of the instantaneous values of the voltage during one complete cycle;

 

 

"Wiring Regulations" means the Electricity (Wiring) Regulations.

 

 

PART II

ADMINISTRATION AND GENERAL

 

 

3.  (1)  There shall be a Chief Electrical Inspector and such electrical inspectors as may be considered necessary.

Chief Electrical Inspector and electrical inspectors

 

(2)  Subject to the directions of the Minister, the Chief Electrical Inspector shall administer these Regulations.

 

 

(3)  No person shall be appointed-

 

 

(a)        as the Chief Electrical Inspector unless he is a Chartered Electrical Engineer with experience in the electricity supply industry to the satisfaction of the Minister; or

 

 

(b)        as an electrical inspector unless he has had experience in the electricity supply industry to the satisfaction of the Minister.

(As amended by G.N. No. 34 of 1964)

 

 

4.  (1)  Subject to the provisions of sub-regulations (2) and (3), these Regulations shall apply to every undertaker.

Application

 

(2)  Parts III, IV and V shall not apply-

(a)        to the construction, installation, quality, alteration, operation, control, protection, inspection and testing of the parts of an undertaker's works which are used exclusively for mining or factory purposes at a mine or factory where such parts comply with the electrical provisions of any written law or regulations relating to such construction, installation, quality, alteration, operation, control, protection, inspection and testing at a mine or factory;

(b)        to the construction, installation and quality of an undertaker's works, or any part thereof, installed or erected, or for the installation or erection of which an agreement was entered into, before the commencement of Part III or Parts IV and V, as the case may be, until such works or part thereof are altered or replaced after such commencement.

 

 

(3)  Regulation 27 shall not apply to the construction of a building by an undertaker for the accommodation, of any of his works where such building complies with any written law or by-law relating to its construction.

(As amended by G.N. No. 34 of 1964 and S.I. No. 157 of 1965)

 

 

5.  (1)  Where an undertaker in pursuance of these Regulations declines-

(a)        to connect a consumer's installation or any part thereof with the undertaker's electric lines; or

(b)        to give or continue to give a supply of electricity; or

(c)        to recommence a supply of electricity after it has been disconnected;

Procedure as to settlement of disputes

 

the undertaker shall give notice to the consumer On Form No l stating the reasons for so declining.

 

 

(2)  Where a difference arises-

(a)        between a consumer and an undertaker-

 

 

(i)         with reference to a notice given in terms of sub-regulation (1) or (2) of regulation 11; or

 

 

(ii)        with reference to a consumer's installation to which the provisions of regulation 10 apply; or

 

 

(iii)       concerning the measurement of electricity; or

 

 

(iv)       in the application of these Regulations generally;
or

(b)        between one undertaker and another in connection with these Regulations;

 

 

the Minister may order an inquiry to be held in terms of section thirtyfive of the Act.

 

 

6.  (1)  Subject to the provisions of sub-regulation (4), before giving a supply of electricity to a consumer the undertaker shall declare in writing to that consumer the standard type of current and number of phases, the standard frequency and the standard voltage at which the undertaker proposes to deliver the electricity to the supply terminals.

Declared method of supply to new consumers

 

(2)  Subject to the provisions of sub-regulation (4), for the purposes of sub-regulation (1)-

(a)        the standard type of current and number of phases shall be alternating current, one or three phases;

(b)        the standard frequency shall be fifty cycles per second;

(c)        the standard voltage shall be-

 

 

(i)         225 volts phase to neutral for a single-phase supply; or

 

 

(ii)        390 volts phase to phase for a three-phase supply.

 

 

(3)  Subject to the provisions of sub-regulation (4), the standards referred to in paragraphs (a), (b) and (c) of sub-regulation (2) shall be constantly maintained subject to a permissible variation-

(a)        of frequency, between a lower limit of 48.75 cycles per second and an upper limit of 51.25 cycles per second

(b)        of voltage-

 

 

(i)         between a lower limit of 210 volts phase to neutral and an upper limit of 240 volts phase to neutral in the case of a single-phase supply;

 

 

(ii)        between a lower limit of 365 volts phase to phase and an upper limit of 415 volts phase to phase in the case of a three-phase supply.

 

 

(4)  Departures from the provisions of sub-regulation (1), (2) or (3) may be made by an undertaker-

(a)        by agreement with a consumer to whom it is intended to give an individual supply of electricity from a distributing main to be used solely for the purposes of that one consumer; or

(b)        by agreement with each consumer in a group of consumers to whom it is intended to give a supply of electricity from a common distributing main for the group; or

(c)        in giving a supply of electricity at high voltage in terms of a published tariff; or

(d)        in giving a special supply of electricity for purposes outside the terms of the undertaker's published tariffs:

 

 

Provided that a departure made in terms of this sub-regulation to a consumer shall not adversely affect any other consumer.

 

 

(5)  Before giving a supply of electricity to a consumer in accordance with the provisions of sub-regulation (4), the undertaker shall declare in writing to that consumer the type of current and, if alternating current, the number of phases and frequency and the voltage at which the undertaker proposes to deliver the electricity to the supply terminals.

 

 

(6)  Where a supply of electricity is given in terms of sub-regulation (4), it shall be constantly maintained as declared in sub-regulation (5) subject to a permissible variation-

(a)        of frequency, if alternating current, not exceeding two and one-half per centum above or below the declared frequency;

(b)        of voltage, not exceeding ten per centum above or below the declared voltage except where the special agreement for the supply stipulates a different permissible voltage variation.

 

 

(7)  Before giving a bulk supply of electricity to another undertaker for redistribution, the supplying undertaker shall declare in writing to the receiving undertaker the type of current and, if alternating current, the number of phases and frequency and the voltage at which it is proposed to deliver the electricity:

 

 

Provided that where the bulk supply is alternating current intended for redistribution to consumers to whom the provisions of sub-regulations (1), (2) and (3) apply-

(i)         the declared frequency shall be fifty cycles per second;

(ii)        such frequency shall be constantly maintained subject to the permissible variations set out in paragraph (a) of sub-regulation (3);

(iii)       any limits to voltage variation agreed between the two undertakers shall be such as will not adversely affect any consumer in respect of the provisions of paragraph (b) of sub-regulation (3).

 

 

(8)  Except for causes beyond the control of the undertaker and subject to the provisions of regulation 8-

(a)        any permissible variation provided for in this regulation to a declared frequency of fifty cycles per second shall be conpensatorily adjusted to give a mean frequency of fifty cycles per second as far as practicable in each continuous period of twenty-four hours;

(b)        any permissible variation provided for in this regulation to a declared voltage may be exceeded during control operations on the system for a period not longer than ten consecutive minutes.

 

 

(9)  Subject to the terms and conditions of a contract of supply between an undertaker and a consumer entered into on or after the 1st December, 1961, nothing in this regulation provided shall prevent such undertaker and consumer by agreement terminating the contract of supply made in terms of sub-regulations (1), (2) and (3) and substituting therefor a new contract of supply made in terms of sub-regulations (4), (5) and (6), or vice versa, provided that no other consumer is adversely affected thereby.

 

 

7.  (1)  Where an undertaker continues to give a supply of electricity to a consumer on and after the 1st December, 1961, in accordance with a contract or verbal agreement to supply existing at but made before such date, the provisions of this regulation shall apply to the declared method of supply.

Declared method of supply to existing consumers

 

(2)  The supply of electricity under an existing contract or verbal agreement which requires the undertaker to deliver the electricity to the supply terminals-

(a)        as alternating current, one or three phases;

(b)        at a frequency of fifty cycles per second;

(c)        at a voltage of-

 

 

(i)         220 volts or 230 volts phase to neutral for a single-phase supply; or

 

 

(ii)        380 volts or 400 volts phase to phase for a three-phase supply;

 

 

shall, in the absence of an agreement to the contrary, be constantly maintained subject to the permissible variations set out in sub-regulation (4) and shall continue to be the declared method of supply for such period of time as is determined by sub-regulation (6).

 

 

(3)  The supply of electricity under an existing contract or verbal agreement which requires the undertaker to deliver the electricity to the supply terminals at values differing from those set out in paragraphs (a), (b) and (c) of sub-regulation (2) shall be constantly maintained subject to the permissible variations set out in sub-regulation (5) and shall continue to be the declared method of supply for such period as is determined in the manner set out in sub-regulation (7).

 

 

(4)  There shall be a permissible variation for the purposes of sub-regulation (2)-

(a)        of frequency, between a lower limit of 48.75 cycles per second and an upper limit of 51.25 cycles per second;

(b)        of voltage-

 

 

(i)         between a lower limit of 210 volts phase to neutral and an upper limit of 240 volts phase to neutral in the case of either a 220 volts or a 230 volts single-phase supply;

 

 

(ii)        between a lower limit of 365 volts phase to phase and an upper limit of 415 volts phase to phase in the case of either a 380 volts or 400 volts three-phase supply.

 

 

(5)  Except where the existing contract or verbal agreement to supply includes specific terms for permissible variations which shall prevail during the continuation of the contract or verbal agreement, there shall be a permissible variation for the purposes of sub-regulation (3)-

(a)        of frequency, if alternating current, not exceeding two and one-half per centum above or below the normal frequency;

(b)        of low voltage or medium voltage, not exceeding six per centum above or below the normal voltage;

(c)        of high voltage, not exceeding ten per centum above or below the normal voltage.

 

 

(6)  The declared method of supply to a consumer set out in sub-regulation (2) shall continue in force until-

(a)        termination of the existing contract or verbal agreement to supply or permanent discontinuance of supply to that consumer; or

(b)        there is an agreement made between the undertaker and the consumer to terminate the existing contract or verbal agreement to supply and to substitute therefor a new contract of supply which shall be subject to the provisions of regulation 6; or

(c)        the 1st December, 1966;

 

 

whichever is the earliest.

 

 

(7)  The declared method of supply to a consumer set out in sub-regulation (3) shall continue in force until-

(a)        termination of the existing contract or verbal agreement to supply or permanent discontinuance of supply to that consumer; or

(b)        there is an agreement made between the undertaker and the consumer to terminate the existing contract or verbal agreement to supply and to substitute therefor a new contract of supply which shall be subject to the provisions of regulation 6;

 

 

whichever is the earlier.

 

 

(8)  Before the date referred to in paragraph (c) of sub-regulation (6), except where there has been a prior termination of the existing contract or verbal agreement in terms of paragraph (a) or (b) of that sub-regulation, the undertaker-

(a)        shall serve on each consumer affected by the provisions of that sub-regulation a notice declaring the new method of supply; or

(b)        shall declare the new method by publication in a newspaper circulating in the area affected.

 

 

(9)  On and after the date referred to in paragraph (c) of sub-regulation (6), except where there has been a prior termination of the existing contract or verbal agreement in terms of paragraph (a) or (b) of that sub-regulation, each consumer affected by the provisions of that sub-regulation and of sub-regulation (8) shall be deemed to be a consumer to whom the provisions of regulation 6 apply:

 

 

Provided that the permissible variation referred to in sub-regulation (3) of regulation 6 shall only apply in the absence of an agreement to the contrary.

 

 

(10)  Subject to any terms of a contract of supply between the undertaker and another undertaker existing at but made before the 1st December, 1961, the provisions of sub-regulation (7) of regulation 6 shall apply, mutatis mutandis, to such existing contract during its continuation.

 

 

(11)  The provisions of sub-regulation (8) of regulation 6 shall apply, mutatis mutandis, to permissible variations of frequency and voltages referred to in this regulation.

 

 

8.  (1)  Subject to the provisions of sub-regulation (2), from the time an undertaker begins to supply electricity through a distributing main or service line, he shall maintain a supply of electricity in terms of the agreement sufficient for the use of each consumer entitled for the time being to be supplied therefrom and that supply shall be constantly maintained to each consumer without change-

(a)        in the declared method of supply set out in regulation 6 or 7 except as provided for therein;

(b)        in the relationship between the neutral conductor and earth or between the neutral conductor and any phase conductor;

(c)        in the phase rotation;

Undertaker to provide constant supply

 

except by agreement in writing between an undertaker and a consumer provided that no other consumer is adversely affected thereby.

 

 

(2)  An undertaker shall not lessen or discontinue a supply which is required to be constantly maintained in terms of sub-regulation (1) except-

(a)        where permitted by the provisions of section fourteen of the Act; or

(b)        where required or permitted by the provisions of these Regulations.

 

 

9.  (1)  An undertaker may temporarily lessen or discontinue a supply of electricity referred to in regulation 8-

(a)        without prior notice to a consumer likely to be affected-

Undertaker may lessen or discontinue supply

 

(i)         where such action is necessary to prevent danger to life or damage to property; or

 

 

(ii)        in an emergency, from whatsoever cause arising including any political cause, to ensure the proper working of the undertaking or of any other undertaking with which it is interconnected; or

 

 

(iii)       by the automatic operation of a protective device installed to disconnect a supply of electricity in fault conditions; or

 

 

(iv)       by the automatic or hand operation of a device installed to disconnect a supply of electricity in terms of the conditions or agreement to supply; or

(b)        on giving not less than twentyfour hours' notice-

 

 

(i)         for the purposes of making alterations or additions to a system; or

 

 

(ii)        for normal maintenance work; or

 

 

(iii)       for testing a device referred to in subparagraph (iii) or (iv) of paragraph (a).

 

 

(2)  The normal supply of electricity shall be resumed as soon as it is safe and expedient to do so after a temporary lessening or discontinuance referred to in sub-regulation (1).

 

 

(3)  The notice required in terms of paragraph (b) of sub-regulation (1) shall state the period during which the supply may be affected and shall-

(a)        be served in accordance with the provisions of section thirtyseven of the Act; or

(b)        be published in a newspaper circulating in the area affected.

 

 

(4)  In temporarily lessening or discontinuing a supply of electricity in the circumstances set out in sub-paragraph (ii) of paragraph (a) of sub-regulation (1), the undertaker, unless all his consumers are affected thereby, may select which consumer or group of consumers shall have a supply so lessened or discontinued.

 

 

10.  (1)  An undertaker shall not permanently connect a consumer's installation or part thereof with his low-voltage or medium-voltage electric lines if he or a person authorised by him is aware that the connection, if made, would cause a dangerous leakage of electricity from such installation or part thereof.

Undertaker shall not permanently connect

 

(2)  An undertaker shall not permanently connect a consumer's installation or part thereof with his high-voltage electric lines unless he or a person authorised by him is satisfied that the high-voltage portion of the consumer's installation is of a standard of construction and safety not less than that required for an undertaker's high-voltage works in terms of these Regulations.

 

 

(3)  Where an undertaker does not permanently connect a consumer's installation or part thereof under the provisions of sub-regulation (1) or (2), he shall give immediate notice to the consumer on Form No. 1 stating the reasons therefor.

 

 

11.  (1)  An undertaker may refuse to give or, subject to the provisions of regulation 12, to continue to give a supply of electricity to a consumer's installation or part thereof unless the undertaker or a person authorised by him is reasonably satisfied that such installation or part thereof-

(a)        complies with the Wiring Regulations; or

(b)        in the case of an installation used for mining purposes, has been subjected to an insulation resistance test and the undertaker or a person authorised by him is satisfied with the result of such test; or

(c)        had been connected with the undertaker's lines and had been supplied with electricity before the 1st December, 1961, and-

Undertaker not compelled to commence supply

 

(i)         such installation had continued to function satisfactorily up to the present time;

 

 

(ii)        the installation is to be or is being continued in use only within the limits of the maximum power for which it was originally intended;

 

 

(iii)       there are no grounds for supposing that the installation will fail to continue to function satisfactorily for a further reasonable period without risk of danger.

 

 

(2)  Where an undertaker does not give or continue to give a supply of electricity under the provisions of sub-regulation (1), he shall give immediate notice to the consumer on Form No. 1. stating the reasons therefor.

 

 

12.  (1)  Where an undertaker in giving a supply of electricity has reasonable grounds for supposing that a consumer's installation or part thereof-

(a)        does not comply with the provisions of sub-regulation (1) or (2) of regulation 10; or

(b)        does not comply with the provisions of paragraph (a), (b) or (c) of sub-regulation (1) of regulation 11; or

(c)        is being operated in such a way as to endanger any person or as to cause or as is likely to cause damage to property; or

(d)        is interfering with or is likely to interfere with the efficient supply of electricity to any other consumer;

Discontinuance of supply

 

the provisions of this regulation shall apply.

 

 

(2)  Where the undertaker is satisfied that immediate action is justified in the consumer's interests or in the public interest as a result of any of the circumstances set out in paragraphs (a), (b), (c) and (d) of sub-regulation (1), he may forthwith discontinue the supply of electricity without prior notice.

 

 

(3)  Where an undertaker has discontinued a supply of electricity in terms of sub-regulation (2), he shall give immediate notice to the consumer on Form No. 1 stating the reasons therefor.

 

 

(4)  Where the undertaker is not satisfied that immediate action is justified in terms of sub-regulation (2), he may arrange to make a detailed inspection and test of the consumer's installation either-

(a)        by verbal agreement with the consumer; or

(b)        where verbal agreement is impossible, by serving written notice on the consumer requiring the consumer to permit the undertaker or a person authorised by him to make such inspection and test.

 

 

(5)  Where the undertaker-

(a)        makes the inspection and test referred to in sub-regulation (4) and is satisfied that the provisions of paragraph (a), (b), (c) or (d) of sub-regulation (1) apply to the consumer's installation or part thereof; or

(b)        is unable to make such inspection and test because of the failure or refusal of the consumer to permit such inspection and test;

 

 

the undertaker shall, unless he has to take immediate action in terms of sub-regulation (2), give notice to the consumer on Form No. 1 specifying the defect or default.

 

 

(6)  Where the consumer fails to remedy a defect or default within seven days of receiving the notice referred to in sub-regulation (5), the undertaker may discontinue the supply of electricity forthwith on giving notice to the consumer on Form No. 1 stating the reasons for such discontinuance.

 

 

(7)  The undertaker may restrict any discontinuance in the supply of electricity made in terms of this regulation to that portion of the consumer's installation which the undertaker considers to be defective, provided that the sound portion of the consumer's installation has been segregated therefrom and is capable of operating safely.

 

 

(8)  Subject to the settlement of the dispute in terms of regulation 5, an undertaker shall not recommence a supply of electricity to a consumer's installation or part thereof which has previously been discontinued under the provisions of this regulation until the defect or default which led to the discontinuance has been remedied to the undertaker's satisfaction and in accordance with the requirements of regulation 10.

 

 

13.  (1)  Every section of an undertaker's works, including cables and overhead lines, which is in such a faulty condition as to have caused or as to be likely to cause death or injury to any person or damage to any property shall, on such condition becoming known to the undertaker or to a person authorised by him to operate the section, be disconnected from the supply of electricity forthwith and shall not be reconnected until the faulty condition of the section has been remedied.

Disconnection of works in certain circumstances

 

(2)  Every section of an undertaker's works, including cables and overhead lines, which, because of a faulty condition, is causing interference with the use of a telegraph line shall, on the faulty condition becoming known to the undertaker or to a person authorised by him to operate the section, be disconnected from the supply of electricity and shall not be reconnected until the faulty condition of the section has been remedied.

 

 

(3)  Nothing in sub-regulation (1) or (2) provided shall prevent the temporary reconnection of a section referred to therein to a supply of electricity for testing purposes where such temporary reconnection can be made without risk to life or property.

 

 

14.  (1)  No undertaker shall, without the consent in writing of the Postmaster-General given in terms of regulation 11 of the Lines Protection Regulations-

(a)        except in the case of a conductor used solely for earthing purposes, connect with earth a conductor of an electric line which is connected to an alternating current system:

            Provided that-

Connection of system with earth. Cap. 795 of the 1971 Edition of the Laws

 

(i)         the star or neutral point of a generator or transformer; or

 

 

(ii)        one pole of a generator or transformer directly connected to a single-phase, two-wire, low-voltage or medium-voltage electricity supply line;

            may, without such consent, be connected with earth at the point of generation or transformation; or

(b)        connect with earth a conductor of an electric line which is connected to a direct-current system; or

(c)        use the general mass of earth as part of the return of a circuit connected to an electric line, other than the return necessary to operate protective devices on that line.

 

 

(2)  On a single-phase two-wire or three-phase four-wire distribution system operating at low voltage or medium voltage, at least one generator or transformer winding directly supplying that voltage shall have one pole or its neutral point if single phase or its neutral point if three-phase earthed:

 

 

Provided that where precautions are taken against a breakdown of insulation, the neutral point need not be earthed on a low-voltage or medium-voltage system used in an undertaker's works where such system does not supply a consumer.

 

 

(3)  Where a high-voltage system is designed for operating with an earthed neutral, the neutral of the generator or transformer winding shall be earthed at the point of generation or transformation:

 

 

Provided that where the generator or transformer feeds a remote transformer, via a transmission line, the neutral of the generator or transformer need not be earthed if the neutral of the remote transformer is earthed at the point of the remote transformation.

 

 

(4)  On a high-voltage system designed for operating with an insulated neutral-

(a)        provision shall be made to indicate a displaced neutral;

(b)        precautions shall be taken against a breakdown of insulation.

 

 

(5)  Save for operational purposes on a high-voltage system, a conductor which is connected to earth in terms of this regulation shall be uninterrupted by a fuse, switch, circuit breaker, link or other means whilst any phase conductor of the system remains live.

 

 

(6)  Where an electrode boiler is installed, the provisions of the Wiring Regulations relating to the earthing of electrode boilers shall apply.

 

 

15.    An undertaker shall comply with the provisions of the Lines Protection Regulations where-

(a)        a cable laid by him crosses or is in close proximity to an underground telegraph line; or

(b)        an overhead line installed by him crosses or is in close proximity to an overhead telegraph line.

Protection of telegraphs

 

16.    Subject to the provisions of section thirty-two of the Act, an undertaker shall restrict access to his works to himself and to persons authorised to have access to such works.

Access to undertaker's works

 

17.  (1)  For the guidance of a person authorised by the undertaker to operate, control or work on the undertaker's works, whether under supervision or otherwise, where high voltage may be present the undertaker shall issue general instructions regarding the working procedure to be followed to ensure maximum safety.

Guidance and instructions

 

(2)  The general instructions referred to in sub-regulation (1) shall, where the person is engaged in inspections, tests, cleaning, repairs, painting or maintenance work near live high-voltage conductors or live high-voltage parts, require that person to observe the section clearances set out in the Second Schedule.

 

 

18.  (1)  A consumer shall not be relieved of any liability or responsibility for inspecting, testing or maintaining in a safe condition his own installation by virtue of any obligation to inspect or test placed on an undertaker, a person authorised by him or an electrical inspector by these Regulations.

Inspections and tests

 

(2)  For the purposes of sub-regulation (2) of regulation 10 or sub-regulation (1) of regulation 11, the undertaker may, in lieu of an inspection or test by himself or by a person authorised by him, accept from a consumer a certificate on Form No. 2 given on behalf of the consumer by some other person whom the undertaker considers competent to make such statement that the consumer's installation or part thereof has been inspected and tested in a manner approved by, and with results satisfactory to, the undertaker.

 

 

19.    An undertaker shall retain a copy of these Regulations at each office, depot or service centre attached to his undertaking.

Availability of Regulations

 

PART III

CONSTRUCTION OF UNDERTAKERS' WORKS

 

 

20.  (1)  The undertaker's works shall-

(a)        be sufficient in size and rating to perform their intended functions;

(b)        be designed, constructed, installed, protected where necessary and of such quality to prevent danger;

(c)        be specially designed and constructed or additionally protected where exposed to-

Design and protection of works

 

(i)         the weather; or

 

 

(ii)        wet conditions; or

 

 

(iii)       vermin; or

 

 

(iv)       corrosion; or

 

 

(v)        inflammable surroundings; or

 

 

(vi)       dust; or

 

 

(vii)      explosive atmosphere;

 

 

so as to prevent danger from such exposure.

 

 

(2)  Conductors and live parts, except as otherwise provided for in Part IV or V, shall-

(a)        be fully insulated and mechanically protected where necessary to prevent danger; or

(b)        be so placed and safeguarded as to prevent danger.

 

 

(3)  High-voltage conductors and high-voltage live parts, unless completely surrounded and protected by earthed metal, shall have the minimum section clearances set out in the Second Schedule or shall be so guarded by a protective barrier as to prevent inadvertent touching or dangerous approach by a person standing on any floor-level, walkway, stairway or working platform.

 

 

21.    A switch, fuseswitch, circuit-breaker or isolating link shall-

(a)        be accurately adjusted to make and maintain good contact;

(b)        be provided with an operating handle which shall be insulated from the electrical conductors;

(c)        be arranged so that it cannot accidentally reclose from the open position;

(d)        be arranged to make and break all live poles of the supply simultaneously except in the case of fuses or where an isolating link is intended for use on a circuit not carrying load;

(e)        be designed or constructed so that in breaking a live circuit an arc is not maintained.

Switchgear

 

22.    A fuse shall be designed, constructed, installed and protected in such a manner that-

(a)        it effectively interrupts the circuit current under fault or abnormal overload conditions;

(b)        the fusible portion may be readily removed or replaced without danger.

Fuses

 

23.    An automatic circuit-breaker shall be designed, constructed, installed and protected in such a manner that-

(a)        it effectively interrupts the circuit current under fault or abnormal overload conditions;

(b)        there is no danger from overheating or arcing or the scattering of hot oil when it operates;

Automatic circuit-breakers

 

(c)        where arranged for manual closing, the operating mechanism provides trip-free operation.

 

 

24.    An electrical joint or connection shall be designed, constructed, installed and protected in such a manner that-

(a)        electrical conductivity is maintained satisfactorily;

(b)        its insulation, where insulation is necessary, is suitable for the normal operating voltage;

(c)        its mechanical strength is suited to its location and environment.

Joints and connections

 

25.  (1)  Isolating and protective devices-

(a)        for disconnecting all voltages from any part of a system;

(b)        for starting and stopping every motor;

shall be provided to prevent danger.

Isolating and protective devices

 

(2)  Every part of a system shall be protected from excess current except a control or other circuit where such protection may be undesirable or unnecessary.

 

 

26.  (1)  A switchboard shall be designed, constructed, installed and placed in such a manner that-

(a)        parts which have to be handled or adjusted are readily accessible from the working platform;

(b)        measuring instruments and indicators are observable from such platform:

Switchboards

 

Provided that where such handling, adjustment or observation is made from another position, such additional precautions as are necessary to prevent danger shall be taken.

 

 

(2)  A low-voltage or medium-voltage switchboard which has bare conductors normally so exposed that they can be touched shall-

(a)        be located in an area specially provided or be suitably fenced or enclosed; or

(b)        have a working platform or passageway that has-

 

 

(i)         a firm and even floor;

 

 

(ii)        adequate means of access free from danger;

 

 

(iii)       a clear headroom of not less than 2.1336 metres;

 

 

(iv)       a clear width of not less than 1.2192  metres measured from any bare conductor or a clear width of 2.4384 metres between bare conductors arranged in switchboards on opposite sides of the same passageway.

 

 

27.  (1)  A building constructed by an undertaker for the accommodation of any of his works shall-

(a)        be substantially constructed and designed for its intended purposes;

(b)        be so arranged as to prevent as far as practicable access thereto except by a doorway or gateway;

(c)        enclose such works in such a manner that they cannot readily be interfered with from outside;

(d)        be ventilated, kept dry and made vermin-proof as far as practicable;

(e)        have fixed outside each entrance a notice of durable material inscribed with the word "DANGER" in red letters at least 3.175 centimetres in height together with a red danger-symbol all on a white background;

(f)         have fixed inside printed instructions as to the proper first-aid treatment of persons suffering from electric shock.

Buildings for electrical purposes

 

(2)  A building referred to in sub-regulation (1) below ground level shall-

(a)        have adequate means of access by a door or trapdoor with a staircase or ladder securely fixed and so placed that no live part of a system or conductor shall be within reach of a person thereon; or

 

 

(b)        where a person is to be regularly employed therein and high voltage is present, have the access referred to in paragraph (a) by door and staircase only.

 

 

28.  (1)  Any part of the undertaker's works for the transformation, control, regulation or switching of electricity in the open air shall, except as otherwise provided for in Part IV or V-

(a)        be completely enclosed in a metal casing connected with earth at all points below a height of 3.048 metres from the ground; or

(b)        be mounted on the supports of an overhead line; or

(c)        be enclosed by a fence not less than 1.8288 metres in height fitted with a suitable anticlimbing device for the purpose of preventing access not authorised by the undertaker.

Outdoor substations

 

(2)  A notice of durable material inscribed with the word "DANGER" in red letters at least one and a 3.175 centimetres in height together with a red danger-symbol all on a white background shall be fixed to the metal casing, supports or fence referred to in paragraph (a), (b) or (c) of sub-regulation (1).

 

 

29.  (1)  Metal-work attached to or forming part of a metal or reinforced concrete support and a metal transformer case or metal switch handle mounted thereon shall be connected with earth.

Earthing of metal-work

 

(2)  Metal-work attached to or forming part of a wooden support which is liable to become dangerous because of leakage across or failure of the insulation shall-

(a)        be connected with earth if the metal-work is within 3.048 metres of the ground; or

(b)        where the metal-work is not connected with earth and is more than 3.048 metres above the ground, have effective secondary insulation sufficient to withstand the voltage to earth.

 

 

(3)  Notwithstanding the provisions of sub-regulation (2), where mounted on a wooden support-

(a)        a metal transformer case together with its associated metal-work and a metal switch handle shall be connected with earth;

(b)        a high-voltage switch shall have inserted in the operating rod between the switch handle and the switch an insulator capable of withstanding the normal operating voltage where such switch handle is within 3.048 metres of the ground.

 

 

(4)  A metal cradle or a stay-wire shall-

(a)        be connected with earth; or

(b)        have inserted insulation capable of withstanding the normal operating voltage.

 

 

(5)  Metal armouring or metal sheathing, except sheathing intended for use as a concentric neutral conductor at earth potential, shall-

(a)        be connected with earth;

(b)        have earth continuity maintained by a separate earth conductor across any joint-box or terminal enclosure associated with the cable;

(c)        where the joint-box or enclosure referred to in paragraph (b) is of metal, be bonded thereto.

 

 

(6)  Save as is otherwise provided in these Regulations, any metal-work associated with or forming part of the undertaker's works, unless isolated from and not likely to come into contact with live parts or with earthed metal-work, shall be connected with earth.

 

 

30.  (1)  Where an undertaker provides protective multiple earthing in accordance with the provisions of Part VI, he shall, before supplying a consumer with electricity therefrom, interconnect with his own earthing arrangements the main earthing conductor of the consumer's installation.

Earthing of consumer's installation

 

(2)  In a case other than that set out in sub-regulation (1), the undertaker may, before supplying a consumer with electricity, permit an interconnection between his own earthing arrangements and the main earthing conductor of the consumer's installation, subject to such conditions as the undertaker considers necessary.

 

 

31.    An earth electrode of the undertaker shall be so installed that no voltage gradient shall be maintained at ground-level which may cause danger to life.

Earth electrodes

 

32.    Where metal-work is earthed, the associated earthing system shall be so designed, constructed and maintained that the leakage resulting from contact of negligible resistance between a live conductor or live part and any metal-work connected with earth shall be sufficient to operate the protective device which shall be installed to make that conductor or part dead.

Leakage to earth

 

33.    Nothing in regulation 32 provided shall prevent the use of an arc-suppression coil inserted between the transformer or generator neutral and earth in such a manner as to ensure that in the event of a live conductor or live part coming into contact with earth or with any metal-work connected with earth an arc between that conductor or part and earth shall be immediately suppressed and the voltage of that conductor or part shall be so reduced as to prevent as far as reasonably practicable the risk of accident therefrom.

Arc-suppression coils

 

34.  (1)  A service line shall have a suitable fusible cut-out or circuit-breaker as a protective device placed as near as practicable to the supply terminals on the consumer's premises.

Service lines on consumer's premises

 

(2)  A protective device referred to in sub-regulation (1) shall-

(a)        be supplied and installed by the undertaker or, in the event of agreement between him and the consumer, by the consumer;

(b)        be of adequate rupturing capacity, suitably enclosed and of fire-resisting construction;

(c)        be placed at a position to be selected by the undertaker after consultation with the consumer;

(d)        be inserted in each live conductor and not in any neutral conductor permanently connected with earth.

 

 

(3)  Where a supply of electricity is to be provided at high voltage, provision shall be made whereby-

(a)        the protective device referred to in sub-regulation (1) can be isolated from the service line;

(b)        the consumer can cut off all voltage at or after the supply terminals without danger.

 

 

(4)  Where the consumer installs an unmetered service line or service main on his premises or where a part of the consumer's installation is to be solely operated and controlled by the undertaker, the undertaker shall ensure that such service line, or service main or such part of the installation-

(a)        is suitable for its intended purpose;

(b)        is installed to prevent as far as practicable leakage of electricity to adjacent metal.

 

 

(5)  A line, main or part referred to in sub-regulation (4) shall be subject to the provisions of regulations 10, 11, 12, 13 and 32 and the undertaker shall-

(a)        provide for any disconnection required thereunder;

(b)        advise the consumer of any remedial measures necessary to correct any defect, deficiency, or faulty condition which may exist.

 

 

PART IV

CABLES

 

 

35.  (1)  A cable shall be fully insulated for the normal operating voltage and shall be of a type and construction and shall be laid or installed in a manner suited to its particular environment and having regard to-

(a)        the provisions of paragraphs (a), (b) and (c) of sub-regulation (1) of regulation 20;

(b)        the normal usage of the ground in which any part of it is to be laid;

(c)        foreseeable risk of damage to the cable and danger to persons, property and to other electrical services, water, gas, sewerage and telegraph services, railways and constructional works at or below ground-level.

Construction and installation of cables

 

(2)  A component used with a cable shall be of a type and construction and shall be laid or installed in a manner suited to that cable and having regard to the provisions of-

(a)        sub-regulation (1);

(b)        regulation 24 where a joint or connection is necessary.

 

 

36.  (1)  A high-voltage cable shall be so laid or installed that it is completely surrounded and protected by earthed metal as provided-

(a)        by its own metal sheathing or metal armouring; or

(b)        by an extraneous metallic covering.

Metallic protection for high-voltage cables

 

(2)  A joint, connection or termination of a high-voltage cable shall be surrounded and protected by earthed metal.

 

 

(3)  Notwithstanding the provisions of sub-regulation (1) or (2), the surrounding and protecting by earthed metal referred to therein may be omitted in a power station, substation, switch-room or similar premises designed for electrical purposes, provided that where it is omitted, the high-voltage cable, joint, connection and termination shall-

(a)        have the section clearances required in terms of sub-regulations (3) and (4) of regulation 20; or

(b)        be so guarded by a protective barrier as to prevent inadvertent touching or dangerous approach by a person standing on a normal floor-level, walkway, stairway or working platform.

 

 

37.  (1)  A neutral conductor of a cable shall, at its termination, be permanently identified so that it is readily and uniformly distinguishable from other conductors.

Identification and testing

 

(2)  Where two or more cables forming part of different circuits terminate at adjacent positions, each circuit shall-

(a)        be permanently labelled on its exterior or on its terminating box or component; or

(b)        have other means of identification;

 

 

so that it is readily distinguishable from other circuits.

 

 

(3)  A cable shall be subjected to an insulation test after being laid or installed before being connected to a supply of electricity but it shall not be so connected if the connection would result in an electrical leakage which might be a danger to persons or property.

 

 

(4)  No cable shall be permanently connected to a supply of electricity unless tests have been made-

(a)        to ensure compliance with the provisions of these Regulations;

(b)        to establish electrical continuity of conductors.

 

 

PART V

OVERHEAD LINES

 

 

38.    The provisions of this Part shall apply to overhead lines other than-

(a)        an overhead crane wire or trolley wire;

(b)        an overhead line consisting entirely of insulated conductors enclosed in earthed metal sheathing or earthed metal armouring;

(c)        a conductor used above ground and in the open air as a fence specially designed for the control of movement of animals;

(d)        an overhead telegraph line;

(e)        an overhead line and pole-mounted or other substation within a fenced enclosure specially erected by the undertaker operating such line and substation for the purpose of prohibiting entry not authorised by him where such fence is not less than 1.8288 metres in height and is fitted with a suitable anti-climbing device.

Application of Part V

 

39.    The constructional requirements of an overhead line shall comply with-

(a)        the provisions of sub-regulation (1) of regulation 20;

(b)        any specific provisions of this Part.

Constructional requirements

 

40.  (1)  Line conductors and earth conductors shall be of copper, cadmium copper, steel-cored copper, aluminium, steel-cored aluminium, aluminium alloy, copper-clad steel, galvanised steel, stainless steel or any compatible combination of these materials.

Materials

 

(2)  Cradle supporting wires and stay-wires shall be of stranded galvanised steel or be of material of not less than equivalent strength and durability.

 

 

(3)  A support shall be of wood, metal or reinforced concrete or a combination of these materials and where wood or metal is used in the construction of a support, such wood or metal shall be protected against decay or corrosion as far as is reasonably practicable. The diameter of a wooden support at a point 1.524 metres from the butt shall be not less than 15.24 centimetres.

 

 

(4)  Supports and the foundations thereof shall be constructed and placed having regard to the characteristics of the ground in which they are embedded and to the load which they are to carry.

 

 

(5)  Insulators shall-

(a)        be of durable materials;

(b)        be designed to withstand the mechanical loading and electrical stresses of normal operating conditions.

 

 

41.  (1)  A line conductor near a building or other permanently raised position existing at the time of erection of the line shall-

(a)        if operating at low voltage or medium voltage, be insulated at all places within a distance of 2.088 metres. from any part of such building or raised position; or

(b)        if operating at high voltage, unless completely surrounded and protected by earthed metal, shall have the section clearance or protective barrier referred to in sub-regulation (3) of regulation 20 between it and any part of such building or raised position.

Minimum heights and clearances

 

(2)  Service lines in the terminal span of a connection between an overhead line and a building or in a span between one building and another building shall be insulated conductors.

 

 

(3)  The point of attachment of a service line shall-

(a)        where connected to an overhead line, be at a support except for vertical service connections not exceeding 3.048 metres in length;

(b)        where connected to a building, be at a terminating device securely fixed to the building.

 

 

(4)  Subject to the provisions of regulations 15, 20 and 42, the height above ground of a line conductor shall be not less than the appropriate height set out in the Third Schedule:

 

 

Provided that the height above ground of a low-voltage or medium-voltage insulated line conductor shall be not less than-

(i)         where a service line is used in the terminal span of a connection between an overhead line and a building or in a span between one building and another building, 3.048 metres at any point up to and including the point of attachment to the building where the line does not cross over a road normally accessible to vehicular traffic;

(ii)        where the line does cross over a road normally accessible to vehicular traffic, 4.2672 metres.

 

 

(5)  Subject to the provisions of regulations 15, 20 and 42, the height above a road surface of earth conductors, stay-wires and cradles fitted between supports shall be not less than 5.4864 metres over roads normally accessible to vehicular traffic.

 

 

(6)  The minimum height or clearance required by these Regulations shall be maintained under any conditions of loading and temperature likely to occur in the area concerned.

 

 

(7)  A conductor, other than an earth conductor, leading to or from a transformer or other apparatus at a pole-mounted substation shall, at all points below a height of 3.6576 metres from the ground, be insulated and, in the case of a high-voltage conductor, shall have earthed metal sheathing or screening.

 

 

42.    Where an overhead line crosses a permanent railway track having a gauge of not less than 9.144 centimetres, the following conditions shall apply:

(a)        the height above the rail of an earth conductor, stay-wire or cradle shall be not less than 7.0104 metres and of a line conductor shall be not less than the appropriate height set out in the Fourth Schedule;

(b)        there shall be no joints in the crossing span;

(c)        a crossing shall be made at right angles or as near thereto as practicable:

                Provided that where the angle of crossing is less than 70 degrees, such crossing shall be the subject of a special agreement with the authority responsible for the operation of the railway;

(d)        the length of span at a crossing shall be as short as is reasonably practicable;

(e)        notwithstanding the provisions of sub-regulation (4) of regulation 44, conductors used at a crossing shall be stranded and be not less than 0.1613 square centimetres cross-sectional area copper or its equivalent conductivity.

Overhead lines crossing railway tracks

 

43.  (1)  Where a high-voltage overhead line crosses a low-voltage or medium-voltage overhead line or where line conductors forming part of such different systems are erected on the same supports, provision shall be made to guard against the lower voltage system being charged above its normal voltage by the higher voltage system.

Different voltages in proximity

 

(2)  Where a pilot circuit is installed and operated as part of an overhead line system, the provisions of sub-regulation (1) shall apply and such pilot circuit shall be installed and operated with due regard to any dangers which may arise from its use.

 

 

44.  (1)  In calculating the strength of the various constituent parts, including supports, of an overhead line, the following basic design conditions shall be assumed:

(a)        a minimum temperature of 30 degrees Fahrenheit;

(b)        the wind pressure acting on the projected area of line conductors and supports not exceeding 12.192 metres in height shall be not less than 5.4 kilograms per square metre and of those exceeding 12.192 metres but not exceeding 36.576 metres in height shall be not less than 6.75 kilogramms per square metre. In the case of conductors, earthwires and round, elliptical or hexagonal poles used as supports, the area on which the pressure acts shall be taken as 60 per centum of the projected area and in the case of lattice or composite structures as one and a half times the projected area of the constituent parts on one side. In the design of spans of over 121.192 metres, the assumed wind load on conductors and earthwires may be reduced to 70 per centum of the calculated load. In the design of conductor spans, due regard shall be given to the possibility of injurious conductor vibration by wind effects.

Loading conditions and factors of safety

 

(2)  A support shall be designed so that the failing load under operating conditions shall be not less than the resultant of simultaneous horizontal and vertical loads calculated in accordance with these Regulations, multiplied by the following factors:

(a)        where the support is of metal, 2.5;

(b)        where the support is of concrete, 2.5;

(c)        where the support is of wood, 3.5.

 

 

(3)  The load in a line conductor, earth conductor, insulator, joint or cradle component or an associated fitting under operating conditions shall not exceed 50 per centum of its ultimate breaking load.

 

 

(4)  Notwithstanding the provisions of this regulation, the minimum permissible size for a single line conductor shall be such as to have an ultimate breaking load of not less than 359.55 kilogramms and shall be not less in gauge than No. 10 British Standard Wire Gauge.

 

 

45.  (1)  Where a protective device is installed in terms of regulation 32 to make a line conductor dead, the earthing system of the overhead line with which the system is associated shall be tested at at least one point by the undertaker or by a person authorised by him-

(a)        before commissioning such overhead line;

(b)        thereafter at intervals of not more than six years;

and repaired if necessary.

Periodic testing and inspecting

 

(2)  The purpose of a test made in terms of sub-regulation (1) shall be to ensure that the leakage resulting from contact of negligible resistance between a line conductor and any metal-work connected with earth is sufficient to operate the protective device.

 

 

(3)  An overhead line, pole-mounted substation, outdoor substation and support shall be inspected from ground level or above by the undertaker or by a person authorised by him-

(a)        within six years after the 1st December, 1961, if erected before that date;

(b)        before commissioning, if erected on or after that date;

(c)        in all cases thereafter at intervals not exceeding six years after the date of inspection referred to in paragraph (a) or (b);

and repaired if necessary.

 

 

(4)  A test or inspection made in terms of this regulation shall be recorded by the person making the test or inspection and such record shall be retained by the undertaker until the next test or inspection is made.

 

 

46.    There shall be fixed in a prominent position at every pole-mounted substation a notice of durable material inscribed with the word "DANGER" in red letters at least 3.175 centimetres in height, together with a red danger-symbol all on a white background.

Warning notices

 

47.    In order to prevent as far as is reasonably practicable climbing which has not been authorised by the undertaker, an anti-climbing device shall be fitted-

(a)        at every support for a pole-mounted substation;

(b)        at every support which has broken surfaces within 3.048 metres of the ground.

Unauthorised climbing

 

PART VI

PROTECTIVE MULTIPLE EARTHING

 

 

48.    On any part of his system where an undertaker is satisfied that more than one connection with earth of a pole or neutral point referred to in sub-regulation (2) of regulation 14 is necessary in order to improve the general factor of safety in relation to earthing of metal-work, the method of providing any additional connections shall-

(a)        be in accordance with the provisions of this Part;

(b)        be known as protective multiple earthing or P.M.E.

Description

 

49.    Before providing protective multiple earthing, an undertaker shall obtain the consent in writing of the Postmaster-General in terms of regulation 11 of the Lines Protection Regulations.

Consent Cap. 795 of the 1971 edition

 

50.    Protective multiple earthing shall-

(a)        only be applied to mains and associated service lines operating at low voltage or medium voltage;

(b)        when so applied, extend to every such main and line of a group supplied with electricity from a common transformer at the said voltage:

            Provided that no such main, line or group shall be directly interconnected in a permanent manner with any other main, service line or group supplied with electricity from any part of another system not similarly earthed.

Limitations

 

51.    A transformer which is to supply the low voltage or medium voltage to a main or service line provided with protective multiple earthing shall be so arranged that-

(a)        an earthing connection is taken from the metal core or metal-work closely associated with the higher voltage winding to an earth electrode;

(b)        another earthing connection is taken from the neutral point on the low-voltage or medium-voltage winding to the same earth electrode or to another earth electrode with its own resistance area.

Connections at transformer

 

52.  (1)  Where a cable is used in a main or service line provided with protective multiple earthing and is laid underground, such cable shall-

(a)        have a neutral conductor of the same material as, and be of a cross-sectional area not less than, any phase conductor;

(b)        have metal sheathing or metal armouring.

Use of cables

 

(2)  The metal sheathing or metal armouring or, if the cable has both metal sheathing and metal armouring, the metal sheathing and the metal armouring and the neutral conductor referred to in sub-regulation (1) shall be bonded together and also bonded to-

(a)        the earthing connection referred to in paragraph (b) of regulation 51 at the transformer position;

(b)        an earth electrode installed-

 

 

(i)         by the undertaker at points at or near the end of each distributing main or service line; or

 

 

(ii)        by the consumer at or on his premises by arrangement with and to the satisfaction of the undertaker; or

 

 

(iii)       by the undertaker and the consumer in accordance with the provisions of sub-paragraphs (i) and (ii).

 

 

53.  (1)  Where an overhead line is used in a distributing main or service line provided with protective multiple earthing, such line shall-

(a)        have a neutral conductor of the same material as, and of a cross-sectional area not less than, any phase conductor; or

(b)        have two neutral conductors of the same material as, and each of a cross-sectional area not less than one-half, that of any phase conductor.

Use of overhead lines

 

(2)  The neutral conductor or the two neutral conductors referred to in paragraph (a) or (b) of sub-regulation (1) shall be bonded to-

(a)        the earthing connection referred to in paragraph (b) of regulation 51 at the transformer position;

(b)        earth electrodes installed-

 

 

(i)         by the undertaker at regular intervals as far as practicable along the route of the line, at branching points and at the final pole of each main or service line remote from the supply transformer; or

 

 

(ii)        by the consumer at or on his premises by arrangement with and to the satisfaction of the undertaker; or

 

 

(iii)       by the undertaker and the consumer in accordance with the provisions of sub-paragraphs (i) and (ii).

 

 

54.  (1)  Where an underground cable and an overhead line are used in association with each other in a main or service line provided with protective multiple earthing, the provisions of regulations 52 and 53 shall apply respectively to such cable and line except that the bonding to the earth connection at the transformer position referred to in paragraph (a) of sub-regulation (2) of regulations 52 and 53 may be omitted in the case of-

(a)        an underground cable which starts at a position remote from the transformer if such cable is fed from an overhead line; or

(b)        an overhead line which starts at a position remote from the transformer if such line is fed from an underground cable:

Use of cables and overhead lines

 

Provided that the overhead line referred to in paragraph (a) or the underground cable referred to in paragraph (b) has such bonding to the earth connection at the transformer position.

 

 

(2)  At every point where an underground cable and an overhead line referred to in sub-regulation (1) are connected with each other, each neutral conductor of the said cable and line and the metal sheathing or metal armouring of the cable shall be bonded together.

 

 

55.    The provisions of regulation 51, 52, 53 or 54 shall not have been complied with until it has been established that the overall resistance to earth of a neutral conductor-

(a)        is such that the fuse, circuit-breaker or other protective device on the high-voltage side of the transformer will operate safely in the event of a breakdown between the transformer windings;

(b)        does not exceed ten ohms;

(c)        is such that the provisions of regulation 32 relating to electrical leakage or of regulation 33 relating to arc-suppression coils where applicable can be complied with efficiently.

Overall resistance

 

56.    No fuse, switch, circuit-breaker, link or other means for interrupting continuity, other than a bolted link, shall be inserted in a neutral or earth conductor used for protective multiple earthing purposes.

Neutral to be unbroken

 

57.    In complying with the provisions of sub-regulation (1) of regulation 30 and subject to the provisions of regulation 18, the undertaker shall first satisfy himself in regard to the consumer's installation that-

(a)        metal-work enclosing, supporting, or in proximity to or likely to come into contact with the electrical wiring is bonded together by one or more earth-continuity conductors;

(b)        the overall resistance to earth of the consumer's earthing system and the associated earthing system is such that the provisions of regulation 32 relating to earth leakage can be complied with efficiently;

(c)        the provisions of regulation 56 have been complied with on the consumer's side of the supply terminals.

Consumer's earthing

 

PART VII

STANDARDS OF MEASUREMENT

 

 

58.  (1)  The fundamental electrical units of measurement shall be-

(a)        the ohm;

(b)        the ampere;

(c)        the volt;

Fundamental electrical units

 

and the value of each shall be as set out in Part I of the Fifth Schedule.

 

 

(2)  Denominations of standards for the fundamental electrical units referred to in sub-regulation (1) shall be as set out in Part II of the Fifth Schedule.

 

 

(3)  Limits of accuracy attainable in the use of standards denominated in sub-regulation (2) shall be as set out in Part III of the Fifth Schedule.

 

 

59.    The electrical unit for the measurement of electricity shall be the kilowatt-hour and the value of such unit shall be derived from the fundamental units referred to in regulation 58 and shall be as set out in Part IV of the Fifth Schedule.

Derived electrical units of energy

 

60.  (1)  The amount of electricity supplied by the undertaker shall, except where otherwise agreed between the consumer and the undertaker, be ascertained by means of an appropriate meter or meters to be supplied by the undertaker.

Measurement of electricity

 

(2)  In addition to a meter which may be placed upon the premises of a consumer to ascertain the amount of the supply, the undertaker may place upon those premises such meter or other apparatus as he may desire for the purpose of ascertaining or regulating the amount of electricity supplied to the consumer, the number of hours during which the supply is taken, the maximum rate of supply taken by the consumer or any other quantity or time connected with the supply.

 

 

(3)  A meter used by an undertaker for measuring a supply to a consumer of electricity in kilowatt-hours shall have permissible limits of error in registration not exceeding three per centum above nor three per centum below a true and precise registration of kilowatt-hours.

 

 

(4)  If a dispute arises between a consumer and the undertaker with reference to the measurement of electricity, the provisions of regulation 5 shall apply to such dispute.

 

 

PART VIII

OFFENCES AND PENALTIES

 

 

61.  (1)  Subject to the provisions of paragraphs (a) and (b) of sub-regulation (2) of regulation 4 and of sub-regulation (3) of that regulation, an undertaker or a person authorised by him who erects or operates electrical works for or in connection with the generation, transmission, distribution, connection, installation and use of electricity, whether on the premises of the undertaker or the consumer or elsewhere, where such works are constructed, operated, maintained, repaired, tested or inspected otherwise than in accordance with the provisions of these Regulations shall be guilty of an offence.

Offences and penalties

 

(2)  Any person who is guilty of an offence in terms of sub-regulation (1) shall be liable to a fine not exceeding three thousand penalty units or, in default of payment, to imprisonment for a period not exceeding twelve months.

(As amended by Act No. 13 of 1994)

 

 

FIRST SCHEDULE
(Regulation 2)

PRESCRIBED FORMS

 

 

 


 

FORM NO. 1
(Regulations 5, 10, 11 and 12)

THE ELECTRICITY ACT

NOTICE FROM UNDERTAKER TO CONSUMER

 

 

    Notice to a consumer from an undertaker declining a supply of electricity.

From (1)         

                       

                       
(1)Here state full name and address of undertaker

To      (2)        

                       

                       
(2) Here state full name and address of consumer

    IT is hereby declared that a supply of electricity to your premises at-

          (3)         

                       

(3) Here state relevant address

(a)              was not permanently connected;

(b)              was not commenced;

(c)              was discontinued;

(d)              will be discontinued;

                  (a), (b), (c), (d) Delete the words which are not appropriate.

                  (i)    to the whole of;

                  (ii)  to a part of;

                             (i), (ii) Delete the words which are not appropriate.

your electrical installation, in terms of section 14 of the Act, and of (e) regulations

             of the Electricity (Supply) Regulations, because-

(e) Add number of regulation

          (4)         

                       

                       

(4) Here state full reasons

It is recommended that-

          (5)         

                       

                       

                       

(5) Here state recommendations

    The supply of electricity will not be connected or resumed until the defects have been safely remedied.

          (6) Signed        

(6) To be signed and dated by a responsible officer

                at       Date ..................................

                for and on behalf of           

          (7)         

                       

                       

(7) Here state name of undertaker

 

 

 

 

FORM NO. 2
(Regulation 18)

THE ELECTRICITY ACT

NOTICE FROM CONSUMER TO UNDERTAKER

 

 

 

    Notice to an undertaker from a consumer certifying the condition of the consumer's electrical installation.

From   

(Name and address of consumer)

To       

(Name and address of undertaker)

    I attach hereto a certificate in respect of the condition of my electrical installation .

Signed               Date ...........................

                                      (Consumer's signature)

 

I          

(Name and address of certifier)

of        

(Name and address of firm or company)

am a/an           

(Occupation, trade or profession)

and I hereby declare that I am competent to make and sign this certificate and do hereby certify as follows:

    1.  That the electrical installation in entirety/in part comprising    

           

(Description of part)

at        

(Address of premises)

    (a)    was installed by me/by           ; and

(Name and address of contractor or other person)

    (b)    was inspected and tested by me;
 

fully in accordance with the recommendations contained in an edition current at the date of this certificate of the Safety Code for the electrical wiring of premises issued by the Standards Association of Zambia in respect of those sections of the installation falling within the scope of the Safety Code.


    2.  That to the best of my knowledge and belief the said electrical installation in entirety/in respect of the part described-

    (a)    complies with the Wiring Regulations;

    (b)    is in a fit and proper condition to operate safely if connected to the intended supply of electricity;

    (c)    can be so connected without risk of a dangerous electrical leakage occurring,

           

Signature of Certifier

           

Witness

Date at             on ............................................ 19...................

 

 

 

 


 

SECOND SCHEDULE
(Regulations 17 and 20)

 

 

 

SECTION CLEARANCES

                             Minimum clearance from any point on
Normal operating voltageor about the permanent equipment
between bare line conductorswhere a man may be required to stand
                                    (measured from the position of the
                                                                                  feet)-

                                                                                 To the nearest
                                                                              part not at earth
                                                      To the nearest    potential of an
                                                    unscreened live             insulator
                                                   conductor in air       supporting a
                                                                                 live conductor

                                                                  metres                metres

 1.   Not exceeding 15,000 volts                         . .                      2.62128      2.4384

  2.  Exceeding 15,000 volts but not
       exceeding 33,000 volts. .                          2.7432                2.4384

  3.  Exceeding 33,000 volts but not
       exceeding 44,000 volts. .                          2.92608              2.4384

  4.  Exceeding 44,000 volts but not
       exceeding 66,000 volts. .                          3.048                  2.4384

  5.  Exceeding 66,000 volts but not
       exceeding 88,000 volts. .                          3.23088              2.4384

  6.  Exceeding 88,000 volts but not
       exceeding 110,000 volts                               . .                      3.3528        2.4384

  7.  Exceeding 110,000 volts but not
       exceeding 132,000 volts                               . .                      3.53568      2.4384

  8.  Exceeding 132,000 volts but not
       exceeding 165,000 volts                               . .                      3.84048      2.4384

  9.  Exceeding 165,000 volts but not
       exceeding 220,000 volts                               ..                       4.2672        2.4384

10.  Exceeding 220,000 volts but not
       exceeding 275,000 volts                               ..                       4.572          2.4384

11.  Exceeding 275,000 volts but not
       exceeding 330,000 volts                               ..                       5.1816        2.4384

 

NOTES

    (a)  The above provisions concern the means of access for works which are permanently available, such as fixed ladders or platforms attached to structures. The means of access shall also comprise the structures themselves and the tops of circuit breakers of transformers if a man is required to stand on them to carry out work. The provisions do not apply to portable ladders, cradles or similar equipment, the use of which is governed by the general instructions issued by the undertaker in terms of regulation 17.

    (b)  Portable ladders and platforms specially designed for specific maintenance work, and so arranged that they cannot readily be employed in any way other than that intended, shall be considered as permanent means of access for the purpose of safety clearances.

 

 

 

THIRD SCHEDULE
(Regulation 41)

 

 

 

MINIMUM HEIGHTS OF OVERHEAD LINES

                                                                             In any position
Normal operating voltage betweenOver roads normallyexcept where
  line conductors                          accessible tootherwise specified
                                               vehicular trafficin these Regulations

 

1.  Not exceeding 650 volts. .                      5.4864 metres      4.8768 metres

2.  Exceeding 650 volts but not
exceeding 33,000 volts         . .                      5.7912 metres      5.1816 metres

3.  Exceeding 33,000 volts but not
exceeding 88,000 volts         . .                      6.096 metres        6.096 metres

4.  Exceeding 88,000 volts but not
exceeding 132,000 volts       . .                      6.7056 metres      6.7056 metres

5.  Exceeding 132,000 volts but not
exceeding 275,000 volts       . .                      7.0104 metres      7.0104 metres

6.  Exceeding 275,000 volts                           . .                        7.3152 metres           7.3152 metres

 

 

 

FOURTH SCHEDULE
(Regulation 42)

 

 

 

MINIMUM HEIGHTS OF OVERHEAD LINES CROSSING RAILWAY
TRACKS

                                                                                  Minimum height
Normal operating voltage between line conductors                            above rail

 

1.  Not exceeding 33,000 volts    . .       . .       . .       . .                   . .  . .         7.62 metres

2.  Exceeding 33,000 volts but not exceeding 88,000 volts          . .  . .         7.9248 metres

3.  Exceeding 88,000 volts but not exceeding 132,000 volts        . .  . .         8.5344 metres

4.  Exceeding 132,000 volts but not exceeding 275,000 volts      . .  . .         8.8392 metres

5.  Exceeding 275,000 volts                  . .       . .       . .                   . .  . .         9.144 metres

 

 

 

FIFTH SCHEDULE
(Regulations 58 and 59)

 

 

 

PART I

FUNDAMENTAL UNITS

    The fundamental electrical units are the units agreed as such at an international conference on electrical units and standards held in London in October, 1908 (the magnitude thereof being determined on the electromagnetic system of measurement, with reference to the centimetre as the unit of length, the gram as the unit of mass and the second as the unit of time), and comprising-

        (a)  the ohm, the unit of electrical resistance, the value thereof being one thousand million in terms of the centimetre and the second;

        (b)  the ampere, the unit of electrical current, the value thereof being onetenth in terms of the centimetre, the gram and the second;

        (c)  the volt, the unit of electromotive force, the value thereof being one hundred million in terms of the centimetre, the gram and the second.

 

 

PART II

DENOMINATIONS OF STANDARDS

    1.  Electrical Resistance. A standard of electrical resistance denominated one ohm, agreeing in value with the limits of accuracy specified in Part III with that of the fundamental unit in paragraph (a) of Part I, and being the resistance between the copper terminals of the instrument marked "Board of Trade Ohm Standard Verified 1894 and 1909" to the passage of an unvarying electrical current, when the coil of insulated wire forming part of the instrument aforesaid is in all parts at a temperature of fourteen decimal nine degrees centigrade.

    2.  Electrical Current. A standard of electrical current denominated one ampere, agreeing in value within the limits aforesaid with that of the fundamental unit in paragraph (b) of Part I, and being the current which is passing in and through the coils of wire forming part of the instrument marked "Board of Trade Ampere Standard Verified 1894 and 1909" when, on reversing the current in the fixed coils, the change in the forces acting on the suspended coil in its sighted position is exactly balanced by the force exerted by gravity in Teddington in the United Kingdom upon the iridioplatinum weight marked A and forming part of the said instrument.

    3.  Electrical Pressure. A standard of electrical pressure denominated one volt, agreeing in value within the limits aforesaid with that of the fundamental unit in paragraph (c) of Part I, and being onehundredth part of the pressure which, when applied between the terminals forming part of the instrument marked "Board of Trade Volt Standard Verified 1894 and 1909 and 1948", causes that rotation of the suspended portion of the instrument which is exactly measured by the coincidence of the sighting wire with the image of the fiducial mark A before and after the application of the pressure, and with that of the fiducial mark B during the application of the pressure, these images being produced by the suspended mirror and observed by means of the eyepiece.

    4.  The coils and instruments referred to herein are deposited at the National Physical Laboratory at Teddington, Middlesex, in the United Kingdom.

 

 

PART III

LIMITS OF ACCURACY

    The limits of accuracy attainable in the use of the standards denominated in Part II are-

        (a)  for the ohm, within onehundredth part of one per centum;

        (b)  for the ampere, within onetenth part of one per centum;

        (c)  for the volt, within onetenth part of one per centum.

 

 

PART IV

DERIVED ELECTRICAL UNIT OF ENERGY

    The derivation of the kilowatthour as the lawful electrical unit for the measurement of electricity shall be from the fundamental units described in Part I. Thus one watt (the practical unit of power) shall be equal to the amount of energy expended per second by an unvarying current of one ampere with a steady applied voltage of one volt. For the purpose of expressing watts in terms of voltage and resistance, or current and resistance, the steady voltage applied to a constant resistance shall be equal to the unvarying current in amperes multiplied by the value of the resistance in ohms.

 

 

    In an alternating-current circuit the product of the instantaneous value of the amperes and the volts represents the instantaneous value of the power and the algebraic mean value of the instantaneous values over one second shall be the power in watts provided that the frequency is fifty cycles per second. One watt-hour shall be equal to the energy expended in one hour when the power is one watt, and a kilowatt-hour shall be equal to one thousand watt-hours.

 

 

THE ELECTRICITY (WIRING) REGULATIONS

 

 

ARRANGEMENT OF REGULATIONS

 

 

PART I

PRELIMINARY

 

 

Regulation

  1.          Title and commencement

  2.          Interpretation

 

 

PART II

GENERAL

 

 

  3.          Administration

  4.          Application

  5.          Procedure as to settlement of disputes

  6.          Prior notification to undertaker

  7.          Accommodation to be provided

  8.          Meter panels and connections

  9.          Custody of undertaker s property

10.          Disconnection in certain circumstances

11.          Connection of neutral with earth

12.          Protection of telegraphs

13.          Guidance and instructions

14.          Certificate of inspection and test

 

 

PART III

CONSTRUCTION OF CONSUMERS' INSTALLATIONS

 

 

15.          Design and mechanical protection

16.          Electrical protection

17.          Isolation and control position

18.          Earthing of metal-work

19.          Protection against earth leakage

20.          Arc-suppression coils

21.          Earthing of installation

22.          Electrode boilers

Regulation

23.          Auto-transformers

24.          Capacitors

25.          Substations

26.          Outdoor substations

 

 

PART IV

UNDERGROUND CABLES

 

 

27.          Construction and installation

28.          Joints and connections

29.          Metallic protection for high voltage cables

30.          Identification and testing

 

 

PART V

OVERHEAD LINES

 

 

31.          Application of Part V

32.          Constructional requirements

33.          Minimum heights and insulation

34.          Unmetered service lines

35.          Overhead lines crossing railway tracks

36.          Different voltages in proximity

37.          Loading conditions and factors of safety

38.          Periodic testing and inspecting

39.          Danger notices

40.          Unauthorised climbing of supports

 

 

PART VI

PROTECTIVE MULTIPLE EARTHING

 

 

41.          Provision of protective multiple earthing

42.          Consent of Postmaster-General

43.          Limitations

44.          Connections at transformer

45.          Use of cables

46.          Use of overhead lines

Regulation

47.          Use of cables and overhead lines

48.          Overall resistance

49.          Neutral to be unbroken

50.          Separate installation

 

 

PART VII

PRIVATE GENERATION AND SUPPLY

 

 

51.          Private ownership

52.          Protection of generators

53.          Fire precautions

54.          Plant rooms

55.          Protection of batteries

56.          Installation of batteries

57.          Labelling

58.          Interconnection

 

 

PART VIII

OFFENCES AND PENALTIES

 

 

59.          Offences and penalties

FIRST SCHEDULE-Minimum section clearances

SECOND SCHEDULE-Certificate of inspection and test

THIRD SCHEDULE-Minimum heights of overhead lines

FOURTH SCHEDULE-Minimum heights of overhead lines crossing railway tracks

FIFTH SCHEDULE-Minimum requirements for protection of private generators

 

 

SECTION 38-THE ELECTRICITY (WIRING) REGULATIONS

Regulations by the Minister

Federal Government Notice
405 of 1961
Statutory Instrument
157 of 1965
Act
13 of 1994

 

PART I

PRELIMINARY

 

 

1.    These Regulations may be cited as the Electricity (Wiring) Regulations* and shall be deemed to have come into operation on the 1st December, 1961.


* These Regulations made under the repealed Act are continued in operation by section fifteen of the Interpretation and General Provisions Act (Cap. 2).

Title and commencement

 

2.    In these Regulations, unless the context otherwise requires-

Interpretation

 

"cable" means an insulated conductor or an assemblage of such conductors enclosed within a common sheathing;

 

 

"conductor" means a bar, tube, wire or line used for conducting electricity;

 

 

"consumer" means a person, other than an undertaker, who is supplied or who has made application to be supplied with electricity by an undertaker;

 

 

"consumer's installation" means the consumer's electrical wiring together with any electricity consuming device connected with such installation;

 

 

"danger notice" means a notice of durable material inscribed with the word "DANGER" in red letters at least one and one-quarter inches in height together with a red symbol illustrating a skull and crossbones all on a white background;

 

 

"earthed" and "connected with earth" mean connected with the general mass of earth in such manner as will ensure at all times an immediate and efficient discharge of electricity, and cognate expressions shall be construed accordingly;

 

 

"electric line" means a cable, overhead line or other means used or intended to be used for the purpose of conveying, transmitting or distributing electricity together with any casing, coating, covering, tube, pipe or insulator enclosing, surrounding or supporting the same, or any part thereof, or any apparatus connected therewith for the purpose of conveying, transmitting or distributing electricity;

 

 

"electrical inspector" means a person referred to in regulation 3 of the Supply Regulations;

 

 

"extra-low voltage" means normal operating voltage not exceeding 30 volts alternating current or 50 volts direct current;

 

 

"failing load" means a load on a support which, if exceeded, will result in the conductor not being supported in accordance with these Regulations;

 

 

"high voltage" means normal operating voltage exceeding 650 volts;

 

 

"insulated conductor" means a conductor covered with insulation suitable for the normal operating voltage;

 

 

"insulation" means nonconducting material enclosing, surrounding, or supporting a conductor or any part thereof;

 

 

"line conductor" means a conductor of an overhead line;

 

 

"Lines Protection Regulations" means the General Post Office (Lines Protection) Regulations;

Cap. 795 of the 1971 Edition

 

"live" means electrically charged;

 

 

"low voltage" means normal operating voltage exceeding 30 volts alternating current or 50 volts direct current but not exceeding 250 volts;

 

 

"main" means an electric line through which electricity may be supplied or is intended to be supplied by the undertaker to a service line;

 

 

"medium voltage" means normal operating voltage exceeding 250 volts but not exceeding 650 volts;

 

 

"metal armouring" means metal wire or metal tape completely covering a cable and manufactured as an integral part of the cable;

 

 

"metal sheathing" means a continuous and watertight metal sleeve surrounding a cable and manufactured as an integral part of the cable;

 

 

"metal-work" means any metal-work other than-

 

 

(a)        a conductor and its associated live parts; or

 

 

(b)        an earth conductor;

 

 

"overhead line" means a conductor erected above ground and in the open air and includes any pole-mounted substation associated therewith;

 

 

"pole-mounted substation" means transformer equipment, high-voltage switchgear or high-voltage apparatus mounted on a support and associated with the operation and control of an overhead line;

 

 

"private owner" means a person operating a plant which is rated at the site where it is installed at a capacity of less than one hundred kilowatts for the generation and supply of electricity at a voltage in excess of extra-low voltage solely for his own use or for use on his own premises;

 

 

"protective multiple earthing" means more than one connection with earth of the pole or neutral point earthed in terms of sub-regulation (2) of regulation 11;

 

 

" service line" means an electric line through which electricity may be supplied or is intended to be supplied by the undertaker to a consumer either from a main or directly from the premises of the undertaker;

 

 

"Supply Regulations" means the Electricity (Supply) Regulations;

 

 

"supply terminals" means the end of a service line at which the supply of electricity is delivered from such line to the consumer;

 

 

"support" means a structure or pole for supporting an overhead line and includes any stay or strut associated therewith;

 

 

"telegraph" or " telegraph line" means a telegraph or telegraph line, as the case may be, as defined in section two of the Posts and Telegraphs Act;

Cap. 795 of the 1971 Edition

 

"voltage" means the electro-motive force existing between any pair of live conductors forming part of the common supply of electricity or between any part of either of such conductors and earth and, in the case of alternating current, means the virtual voltage or root-mean-square value as determined by the square-root of the mean or average value of the squares of the instantaneous values of the voltage during one complete cycle.

 

 

PART II

GENERAL

 

 

3.    Subject to the directions of the Minister, the Chief Electrical Inspector referred to in regulation 3 of the Supply Regulations shall administer these Regulations.

Administration

 

4.  (1)  Subject to the provisions of sub-regulations (2) and (3) and of regulation 51, the provisions of these Regulations shall apply to every consumer and every private owner.

Application

 

(2)  The provisions of Parts III, IV and V shall not apply to-

(a)        the construction, installation, quality, alteration, operation, control, protection, inspection and testing of the parts of a consumer's or private owner's installation which are used exclusively for mining or factory purposes at a mine or factory where such parts comply with the electrical provisions of any written law or regulations relating to such construction, installation, quality, alteration, operation, control, protection, inspection and testing at a mine or factory;

(b)        the construction, installation and quality of a consumer's or private owner's installation, or any part thereof, installed or erected, or for the installation or erection of which an agreement was entered into, before the 1st December, 1961, until such installation or part thereof is altered or replaced after that date.

 

 

(3)  The provisions of regulation 25 shall not apply to the construction of a substation by a consumer or private owner for the accommodation of a high-voltage part of his installation where such substation complies with any written law or by-law relating to its construction.

(As amended by S.I. No. 157 of 1965)

 

 

5.    Where a difference arises between a consumer and an undertaker in the application of these Regulations, the Minister may order an inquiry to be held in terms of section thirty-five of the Act.

Procedure as to settlement of disputes

 

6.  (1)  Before any work is commenced on a new installation or on any alteration or extension to an existing installation, the consumer or the prospective consumer, as the case may be, shall-

(a)        advise the undertaker in writing with reference to-

Prior notification to undertaker

 

(i)         the purpose, type and extent of the proposed work;

 

 

(ii)        the electrical loading of equipment for which the supply or additional supply, as the case may be, of electricity is required;

(b)        obtain from the undertaker in writing details of-

 

 

(i)         the type of current, number of phases and frequency, if alternating current, and voltage, at which the undertaker proposes to deliver electricity to the supply terminals;

 

 

(ii)        the undertaker's property which is to be accommodated in terms of regulation 7;

 

 

(iii)       the meter panel and connections required in terms of regulation 8;

 

 

(iv)       any omission of the consumer's main fuse or circuit-breaker;

 

 

(v)        earthing requirements;

 

 

(vi)       proposed tariff arrangements.

 

 

(2)  Where the work referred to in sub-regulation (1) is commenced-

(a)        it shall not thereafter be changed in relation to its purpose, type, extent and electrical loading except as may be agreed with the undertaker;

(b)        it shall be executed to suit the undertaker's stated details referred to in paragraph (b) of sub-regulation (1).

 

 

7.  (1)  A consumer requiring a supply of electricity, or a consumer receiving a supply of electricity who requires an alteration in the terms of his original electricity supply agreement involving a change in the undertaker's metering arrangements, shall, unless otherwise agreed in writing with the undertaker, provide all necessary accommodation on his premises for such of the undertaker's property as is necessary to provide the said supply or change in metering arrangements, as the case may be.

Accommodation to be provided

 

(2)  Accommodation referred to in sub-regulation (1) shall be located at a position to be agreed between consumer and undertaker and be of a type, design and size required by the undertaker.

 

 

(3)  Where the accommodation referred to in sub-regulation (1) is not inside a building, it shall be fully weatherproof and have no means of access other than a lockable door.

 

 

(4)  Where the accommodation referred to in sub-regulation (1) is located in a substation, switchroom or similar compartment designed solely for electrical purposes, such place shall have a lockable door and shall not be used for purposes other than accommodating the undertaker's property.

 

 

(5)  Where a group of shops, offices, flats, tenements or workshops is to be erected for occupation by separate tenants or a building is to be converted for such use, and it is intended that each tenant shall have an individually metered supply of electricity, the owner of the building shall-

(a)        provide such accommodation at one or more places as may be required by the undertaker for his meters and other property; and

(b)        ensure that each tenant has-

 

 

(i)         free access to the meter registering the tenant's supply of electricity for checking and inspecting purposes; and

 

 

(ii)        a main switch and fuses or a circuit-breaker necessary for controlling the tenant's supply of electricity situated in that part of the building occupied by the tenant.

 

 

8.    Unless otherwise agreed in writing with the undertaker, a consumer providing accommodation in terms of regulation 7 shall-

(a)        supply and fix in a manner and at a position to be agreed between consumer and undertaker a meter panel of the size, type, design and construction required by the undertaker;

(b)        supply and fix such additional component parts as may be required for the operation of transformer metering where such metering is to be used;

(c)        supply all necessary meter loops and line and load connections;

(d)        where the service line to be used is an overhead line, supply and fix at a position to be agreed between consumer and undertaker internal service mains and roof shackles.

Meter panels and connections

 

9.  (1)  A consumer shall take all reasonable steps necessary to ensure the safe custody of the undertaker's property installed on the consumer's premises for or incidental to the supply of electricity.

Custody of undertaker's property

 

(2)  Accommodation provided by a consumer under the provisions of these Regulations for the undertaker's property shall be maintained by the consumer in a fit and proper state.

 

 

(3)  A consumer on whose premises is situate property belonging to an undertaker for or incidental to the supply of electricity shall not, in relation to the said property-

(a)        permit access thereto to a person other than-

 

 

(i)         the undertaker;

 

 

(ii)        a person authorised by the undertaker;

 

 

(iii)       an electrical inspector;

(b)        unless permitted by the undertaker-

 

 

(i)         remove or attempt to remove the property from its position;

 

 

(ii)        remove or attempt to remove any lock or seal attached to the property;

 

 

(iii)       connect thereto or disconnect therefrom a consumer's installation or other electrical circuit;

 

 

(iv)       alter, adjust, handle, operate, tamper or interfere with the property in any way.

 

 

10.  (1)  Any part of a consumer's installation which is in such a faulty condition as to have caused, or as to be likely to cause, death or injury to any person or damage to any property shall, on such condition becoming known to the consumer or to a person authorised by him to operate the installation-

(a)        subject to the provisions of sub-regulation (2) of regulation 34, be immediately disconnected by that consumer or person from the supply of electricity; and

(b)        subject to the provisions of sub-regulation (3), not be reconnected until the faulty condition of the said part has been remedied.

Disconnection in certain circumstances

 

(2)  Any part of a consumer's installation which due to a faulty condition is causing interference with the use of a telegraph line shall, on the faulty condition becoming known to the consumer or to a person authorised by him to operate the installation-

(a)        subject to the provisions of sub-regulation (2) of regulation 34, be disconnected by that consumer or person from the supply of electricity; and

(b)        subject to the provisions of sub-regulation (3), not be reconnected until the faulty condition of the said part has been remedied.

 

 

(3)  Any part of an installation disconnected in terms of sub-regulation (1) or (2) may be reconnected to a supply of electricity for testing purposes where such temporary reconnection can be made without risk to life or property.

 

 

11.  (1)  No consumer shall, without the consent in writing of the Postmaster-General in terms of regulation 11 of the Lines Protection Regulations-

(a)        except in the case of a conductor used solely for earthing purposes, connect with earth a conductor of an electric line which is connected to an alternating current system:

                Provided that-

Connection of neutral with earth.
Cap. 795 of the 1971 Edition

 

(i)         the star or neutral point of a generator or transformer; or

 

 

(ii)        one pole of a generator or transformer directly connected to a single-phase two-wire low-voltage or medium-voltage electricity supply line;

            may, without such consent, be connected with earth at the point of generation or transformation; or

(b)        connect with earth a conductor of an electric line which is connected to a directcurrent system; or

(c)        use the general mass of earth as part of the return of a circuit connected to an electric line, other than the return necessary to operate protective devices on that line.

 

 

(2)  On a single-phase twowire or three-phase four-wire consumer's installation operating at low voltage or medium voltage supplied from the consumer's own generator or transformer, one generator or transformer winding directly supplying that voltage shall have-

(a)        if single-phase, one pole or its neutral point earthed;

(b)        if three-phase, its neutral point earthed.

 

 

(3)  Where a consumer's installation operates at a high voltage and is designed for operating with an earthed neutral, the neutral of the generator or transformer winding shall be earthed at the point of generation or transformation:

 

 

Provided that where the generator or transformer feeds a remote transformer, via a transmission line, the neutral of the generator or transformer need not be earthed if the neutral of the remote transformer is earthed at the point of the remote transformation.

 

 

(4)  On a consumer's installation which is high voltage and designed for operating with an insulated neutral-

(a)        provision shall be made to indicate a displaced neutral;

(b)        precautions shall be taken against a breakdown of insulation.

 

 

(5)  Save for operational purposes on a consumer's high-voltage installation, a conductor which is connected to earth in terms of this regulation shall be uninterrupted by a fuse, switch, circuit-breaker, link or other means whilst any phase conductor of the installation remains live.

 

 

12.    A consumer shall comply with the provisions of the Lines Protection Regulations where-

(a)        a cable laid by him crosses or is in close proximity to an underground telegraph line; or

(b)        an overhead line installed by him crosses or is in close proximity to an overhead telegraph line.

Protection of telegraphs

 

13.  (1)  For the guidance of a person authorised by the consumer to operate, control or work on or near the consumer's installation, whether under supervision or otherwise, where high voltage may be present the consumer shall issue instructions regarding the working procedure to be followed to ensure maximum safety.

Guidance and instructions

 

(2)  The instructions referred to in sub-regulation (1) shall, where the person is engaged in inspection, testing, cleaning, repairs, painting or constructional or general maintenance work in proximity to live high-voltage conductors, require that person to observe the minimum section clearances set out in the First Schedule.

 

 

14.    A consumer who wishes to supply a certificate for the purposes of sub-regulation (2) of regulation 10 or sub-regulation (1) of regulation 11 of the Supply Regulations, as read with sub-regulation (2) of regulation 18 of those Regulations, that his installation or part thereof has been inspected and tested shall furnish such certificate in the form set out in the Second Schedule.

Certificate of inspection and test

 

PART III

CONSTRUCTION OF CONSUMERS' INSTALLATIONS

 

 

15.  (1)  The consumer's installation-

(a)        shall have conductors-

Design and mechanical protection

 

(i)         sufficient in size and power for the purposes for which the supply of electricity is to be used;

 

 

(ii)        constructed, installed and protected so as to prevent, so far as is reasonably practicable, danger to person or property;

(b)        shall not be temporarily or permanently added to unless-

 

 

(i)         it has been ascertained that the current rating and condition of the existing installation which will have to carry the additional load and the earthing arrangements are adequate for the increased loading;

 

 

(ii)        the provisions of regulation 6 have been complied with.

 

 

(2)  Where the consumer's installation or any part thereof is exposed to weather, corrosive atmosphere or other adverse conditions, the installation or that part shall be so constructed and, additionally or alternatively, protected as to prevent danger to person or property arising from such exposure:

 

 

Provided that, where the conditions comprise exposure to inflammable surroundings or an explosive atmosphere, the consumer's installation shall be-

(i)         protected by a flameproof enclosure of an appropriate standard of construction; or

(ii)        be of such construction as to prevent danger; or

(iii)       have intrinsically safe characteristics as to prevent danger to person or property.

 

 

(3)  Conductors and live parts of a consumer's installation shall be-

(a)        insulated and further effectively protected where necessary; or

(b)        so placed and safeguarded;

as to prevent, so far as is reasonably practicable, danger to person or property.

 

 

(4)  Medium-voltage conductors and medium-voltage live parts of a consumer's installation shall be-

(a)        completely enclosed in earthed metal which is electrically continuous and adequately protected against mechanical damage; or

(b)        so constructed, installed and protected as to prevent, so far as is reasonably practicable, danger to person or property.

 

 

(5)  Subject to the provisions of regulation 29, high-voltage conductors and high-voltage live parts of a consumer's installation shall-

(a)        be completely surrounded and protected by earthed metal; or

(b)        have the minimum section clearances set out in the First Schedule; or

(c)        be so guarded by a protective barrier as to prevent inadvertent touching or dangerous approach by a person standing at floor-level or on a walkway, stairway or working platform.

 

 

16.  (1)  Every distinct circuit of a consumer's installation shall be protected against excess current by means of a suitable fuse or automatic circuit-breaker-

(a)        of adequate breaking capacity; and

(b)        suitably located and of such construction as to-

Electrical protection

 

(i)         prevent danger from overheating, arcing or the scattering of hot metal when it comes into operation;

 

 

(ii)        permit the ready renewal of the fusible metal without danger to person or property.

 

 

(2)  No fuse, non-linked switch or non-linked circuit-breaker shall be inserted in a conductor connected with earth.

 

 

(3)  A single-pole switch may only be inserted in a live conductor.

 

 

17.  (1)  Except in the case of an unmetered service line, effective means suitably placed for ready operation shall be provided so that all voltage may be cut off from every part of a consumer's installation as may be necessary to prevent danger, and such means shall include a fireman's emergency switch on the exterior of a building where necessary to disconnect a high-voltage discharge-lamp installation or an electrified barrier.

Isolation and control position

 

(2)  An electricity consuming device which requires operation or attention in normal use shall be so installed that adequate means of access and working space are afforded for such operation or attention.

 

 

(3)  An electric motor shall be controlled by an efficient switch or switches for starting and stopping and the said switch or switches shall be so placed as to be readily accessible to and easily operated by the person in charge of the motor.

 

 

18.  (1)  Metal-work of a consumer's installation enclosing, supporting or otherwise associated with conductors operating at a voltage in excess of extra-low voltage shall, where necessary to prevent danger, be connected with earth.

Earthing of metal-work

 

(2)  Metal-work attached to or forming part of a metal or reinforced concrete support and any metal transformer case or metal switch handle mounted thereon shall be connected with earth.

 

 

(3)  Subject to the provisions of sub-regulation (4), metal-work attached to or forming part of a wooden support which is liable to become dangerous because of leakage across or failure of the insulation shall-

(a)        if the metal-work is not more than 3.048 metres above the ground, be connected with earth;

(b)        where the metal-work is more than 3.048 metres above the ground, be connected with earth or have effective secondary insulation sufficient to withstand the voltage to earth.

 

 

(4)  Where mounted on a wooden support-

(a)        a metal transformer-case together with its associated metal-work and any metal switch handle shall be connected with earth;

(b)        a high-voltage switch with a switch handle not more than 3.048 metres above the ground shall have inserted in the operating rod between the switch handle and the switch an insulator capable of withstanding the normal operating voltage.

 

 

(5)  A metal cradle or stay-wire shall-

(a)        be connected with earth; or

(b)        have inserted insulation capable of withstanding the normal operating voltage.

 

 

(6)  Metal armouring or metal sheathing, except sheathing intended for use as a concentric neutral conductor at earth potential, shall-

(a)        be connected with earth;

(b)        have earth continuity maintained by a separate earth conductor across any joint-box or terminal enclosure associated with the cable;

(c)        where the joint-box or enclosure referred to in paragraph (b) is of metal, be bonded thereto.

 

 

(7)  Save as is otherwise provided in these Regulations, any metal-work associated with or forming part of the consumer's installation shall, unless isolated from and not likely to come into contact with live parts or with earthed metal-work, be connected with earth.

 

 

19.  (1)  Every circuit of a consumer's installation shall be protected against the persistence of earth leakage currents liable to be a danger to person or property.

Protection against earth leakage

 

(2)  Where metal-work is earthed in accordance with the provisions of these Regulations, the associated earthing system shall-

(a)        incorporate a protective device which makes any live conductor or live part dead when there is leakage such as is referred to in sub-regulation (1) between that live conductor or live part and any metal-work connected with earth; and

(b)        be so designed, constructed and maintained that the leakage referred to in paragraph (a) is sufficient to operate the protective device.

 

 

20.    In addition to the protective device referred to in paragraph (a) of sub-regulation (2) of regulation 19, an arc-suppression coil may be inserted between the transformer or generator neutral and earth in such a manner as to ensure that, in the event of a live conductor or live part coming into contact with earth or with any metal-work connected with earth, an arc between that conductor or part and earth shall be immediately suppressed and the voltage of that conductor or part shall be so reduced as to prevent, as far as reasonably practicable, danger to person or property.

Arc-suppression coils

 

21.  (1)  Where an undertaker operates a protective multiple earthing system in accordance with the provisions of Part VI of the Supply Regulations and interconnects with his own earthing arrangements the main earthing conductor of the consumer's installation, before supplying a consumer with electricity therefrom an earth electrode or electrodes shall be installed by the consumer at or on his premises by arrangement with and to the satisfaction of the undertaker and shall also be interconnected with the said earthing arrangements.

Earthing of installation

 

(2)  Save as is provided in sub-regulation (1), where there is an interconnection between the earthing arrangements of the undertaker and the main earthing conductor of the consumer's installation, the consumer shall comply with the conditions considered necessary by the undertaker in terms of sub-regulation (2) of regulation 30 of the Supply Regulations.

 

 

(3)  Where there is no interconnection between the earthing arrangements of the undertaker and the main earthing conductor of the consumer's installation, the consumer shall provide and install his own earthing arrangements to ensure compliance with the provisions of these Regulations.

 

 

(4)  An earth electrode of a consumer shall be so installed that no voltage gradient is maintained at ground level which may cause danger to life.

 

 

22.  (1)  In this regulation-

Electrode boilers

 

"electrode boiler" includes an electrode type waterheater.

 

 

(2)  Before connecting an electrode boiler to a supply of electricity, the consumer shall obtain the consent in writing of the Postmaster-General in terms of regulation 11 of the Lines Protection Regulations.

Cap. 795 of the 1971 Edition

 

(3)  An electrode boiler shall-

(a)        be used only on alternating current;

(b)        have an isolating and protecting circuit-breaker.

 

 

(4)  The circuit-breaker referred to in paragraph (b) of sub-regulation (3) shall-

(a)        be of the multi-pole linked type arranged to disconnect the supply from all electrodes simultaneously;

(b)        have an over-current protective device for each electrode;

(c)        have a locking-off device to prevent the electrode boiler inadvertently being made live whilst a person is working thereon;

(d)        if arranged for direct hand operation from a position near to the boiler, be readily accessible and visible to a person using the boiler;

(e)        if not arranged for direct hand operation from a position near to the boiler, have remote control by a hand-operated switch or pushbutton-

 

 

(i)         with a lamp or other instrument to provide visual indication of the "ON" and "OFF" condition of the electricity supply fixed at or near the boiler; and

 

 

(ii)        readily accessible and visible to a person using the boiler;

(f)         where the boiler is to be operated at high voltage, have automatic tripping in the event of phase currents becoming unbalanced to the extent of ten per centum of the full load current of the boiler:

                Provided that-

 

 

(i)         the margin may be increased to fifteen per centum where the higher setting is essential to ensure operational stability;

 

 

(ii)        an inverse time-element device may be associated with the automatic tripping to prevent unnecessary tripping where the unbalance is momentary or of short duration.

 

 

(5)  The earthing system of an electrode boiler shall, in addition to complying with the provisions of regulations 18 and 19, include-

(a)        the bonding together of-

 

 

(i)         the metallic shell and other metal-work of the boiler;

 

 

(ii)        any water pipes or steam pipes of metal in metallic contact with the said shell or other metal-work;

 

 

(iii)       any metal armouring or metal sheathing of a cable providing a supply of electricity to the said boiler;

(b)        the connection of bonded metal-work referred to in paragraph (a) to the neutral conductor and to the main earthing terminal of the consumer's installation.

 

 

(6)  In the case of an electrode boiler the neutral conductor, main earthing conductor and bonding and the connections to such bonding shall have a current-carrying capacity not less than that of any live or phase conductor at all points except in a subsidiary tripping-circuit where the current-carrying capacity shall be in accordance with the designed tripping-circuit current.

 

 

(7)  An electrode boiler of a type other than a three-phase three-electrode balanced-load type shall not be connected to a supply of electricity otherwise than by means of a double-wound transformer situated within the same building as the said boiler or as close thereto as is practicable and on the same premises.

 

 

23.  (1)  An auto-transformer shall not be fed from a circuit operating at a voltage exceeding low voltage unless such auto-transformer is used-

(a)        in motor starting or control-gear; or

(b)        in conjunction with and installed adjacent to a capacitor which is employed for improving the power factor; or

(c)        in a high-voltage discharge-lighting circuit.

Auto- transformers

 

(2)  An auto-transformer shall not be used to supply-

(a)        a socket-outlet;

(b)        a portable appliance unless the auto-transformer is contained therein;

(c)        an electric toy or model;

(d)        earthed concentric wiring;

(e)        an extra-low-voltage circuit.

 

 

(3)  An auto-transformer shall-

(a)        if used for step-up purposes-

 

 

(i)         be supplied only from a system in which the neutral conductor is earthed;

 

 

(ii)        have the neutral conductor connected to the common pole of the primary and secondary windings;

(b)        if used for step-down purposes, have the secondary winding insulated for the maximum voltage likely to be applied to the primary winding.

 

 

(4)  Where an auto-transformer is used for step-up purposes means of isolation required in terms of regulation 17 shall be arranged to disconnect all primary supply conductors simultaneously.

 

 

24.    Save in the case of a capacitor-

(a)        incorporated in apparatus for the sole purpose of radio interference suppression; or

(b)        so small that no risk of electric shock can arise therefrom;

Capacitors

 

a capacitor shall have a high resistance leak or other means for the prompt and automatic discharge of electricity immediately the supply thereto is disconnected.

 

 

25.  (1)  Subject to the provisions of sub-regulation (3) of regulation 4, a substation constructed by a consumer for the accommodation of a high-voltage part of his installation shall-

(a)        be substantially constructed and designed specifically for its intended purposes;

(b)        be so arranged-

Substations

 

(i)         as to prevent, as far as practicable, access thereto except by a doorway or gateway;

 

 

(ii)        that no hinged door opens inwards;

(c)        enclose the said part of the installation in such a manner that it cannot readily be interfered with from outside;

(d)        be ventilated, kept dry and made vermin-proof, as far as practicable;

(e)        have fixed outside each entrance a danger notice;

(f)         have prominently displayed inside printed instructions as to the proper first-aid treatment of persons suffering from electric shock.

 

 

(2)  Subject to the provisions of sub-regulation (3) of regulation 4, a substation referred to in sub-regulation (1) constructed below ground level shall-

(a)        have adequate means of access by a door or trap door with a staircase or ladder securely fixed and so placed that no live part of a system or conductor is within reach of a person thereon; or

 

 

(b)        where a person is to be regularly employed therein, have the access referred to in paragraph (a) by door and staircase only.

 

 

26.  (1)  Any part of the consumer's installation for the transformation, control, regulation or switching of electricity in the open air shall, save as is otherwise provided for in Part IV or V-

(a)        be mounted on the supports of an overhead line; or

(b)        be enclosed by a fence not less than six feet in height fitted with a suitable anti-climbing device for the purpose of preventing access not authorised by the consumer; or

(c)        where the provisions of paragraph (a) or (b) are not complied with, have all parts below the height of ten feet from the ground completely enclosed in a metal casing.

Outdoor substations

 

(2)  A danger notice shall be fixed to the supports, fence or metal casing, as the case may be, referred to in paragraph (a), (b) or (c) of sub-regulation (1).

 

 

PART IV

UNDERGROUND CABLES

 

 

27.  (1)  An underground cable shall be fully insulated for the normal operating voltage and shall be of a type and construction and shall be laid or installed in a manner suited to its particular environment and having regard to-

(a)        the provisions of regulation 15;

(b)        the normal usage of the ground in which any part of it is to be laid;

(c)        foreseeable risk of damage to the cable and danger to persons, property and to other electrical services, water, gas, sewerage and telegraph services, railways and constructional works at or below ground level.

Construction and installation

 

(2)  A component used with an underground cable shall be of a type and construction and shall be laid or installed in a manner suited to that cable and having regard to the provisions.

(a)        sub-regulation (1);

(b)        regulation 28 in circumstances whenever a cable joint or connection is necessary.

 

 

28.    An electrical joint or connection associated with an underground cable shall be designed, constructed, installed and protected in such a manner that-

(a)        electrical conductivity is maintained satisfactorily;

(b)        its insulation, where insulation is necessary, is suitable for the normal operating voltage;

(c)        its mechanical strength is suited to its location and environment.

Joints and connections

 

29.  (1)  Subject to the provisions of sub-regulation (3), a high-voltage underground cable shall be so laid or installed that it is completely surrounded and protected by earthed metal as provided by-

(a)        its own metal sheathing or metal armouring; or

(b)        an extraneous metallic covering.

Metallic protection for high-voltage cables

 

(2)  Subject to the provisions of sub-regulation (3), a joint, connection or termination of a high-voltage underground cable shall be completely surrounded and protected by earthed metal.

 

 

(3)  In a power station, substation, switchroom or similar premises designed for electrical purposes, it shall not be necessary for a high-voltage cable, joint, connection or termination to be completely surrounded and protected by earthed metal where the cable, joint, connection or termination has the minimum section clearances or is guarded by the protective barrier required in terms of sub-regulation (5) of regulation 15.

 

 

30.  (1)  A neutral conductor of an underground cable shall, at its termination, be permanently identified so that it is readily and uniformly distinguishable from other conductors.

Identification and testing

 

(2)  Where two or more underground cables forming part of different circuits terminate at adjacent positions, each circuit shall-

(a)        be permanently labelled on its exterior or on its terminating box or component; or

(b)        have other means of identification;

            so that it is readily distinguishable from other circuits.

 

 

(3)  An underground cable shall be subjected to an insulation test after being laid or installed and before being connected to a supply of electricity, and it shall not be so connected if the connection would result in an electrical leakage which might be a danger to person or property.

 

 

(4)  No underground cable shall be permanently connected to a supply of electricity unless tests have been made-

(a)        to ensure compliance with the provisions of these Regulations and in particular of sub-regulations (l) and (2) and of regulation 19; and

(b)        to establish that there is electrical continuity of conductors.

 

 

PART V

OVERHEAD LINES

 

 

31.    The provisions of this Part shall apply to overhead lines other than-

(a)        an overhead crane wire or trolley wire;

(b)        an overhead line consisting entirely of insulated conductors enclosed in earthed metal sheathing or earthed metal armouring;

(c)        a conductor used above ground and in the open air as a fence specially designed for the control of the movement of animals;

(d)        an overhead telegraph line;

(e)        an overhead line and substation within a fenced enclosure specially erected by the consumer operating such line and substation for the purpose of prohibiting entry not authorised by him where such fence is not less than 1.8288 metres in height and is fitted with a suitable anti-climbing device.

Application of Part V

 

32.  (1)  Line conductors and earth conductors shall be of copper, cadmium copper, steel-cored copper, aluminium, steel-cored aluminium, aluminium alloy, copper-clad steel, galvanised steel, stainless-steel or any compatible combination of these materials.

Constructional requirements

 

(2)  Cradle supporting wires and stay-wires shall be of stranded galvanised steel or a material of a strength and durability not less than that of stranded galvanised steel.

 

 

(3)  A support shall be of wood, metal or reinforced concrete or a combination of these materials and, where wood or metal is used in the construction of a support, such wood or metal shall be protected, as far as is reasonably practicable, against decay or corrosion.

 

 

(4)  The diameter of a wooden support at a point 1.524 metres from the butt shall be not less than 15.24 centimetres.

 

 

(5)  Supports and the foundations thereof shall be constructed and placed having regard to the characteristics of the ground in which they are embedded and to the load which they are to carry.

 

 

(6)  Insulators shall-

(a)        be of durable materials;

(b)        be designed to withstand the mechanical loading and electrical stresses of normal operating conditions.

 

 

33.  (1)  A line conductor near a building or other permanently raised position existing at the time of erection of the line shall-

(a)        if operating at extra-low voltage, low voltage or medium voltage, be insulated at all places within a distance of 1.8288 metres from any part of such building or raised position;

(b)        if operating at high voltage, be completely surrounded and protected by earthed metal or have the minimum section clearances or protective barrier required in terms of sub-regulation (5) of regulation 15 between it and any part of such building or raised position.

Minimum heights and insulation

 

(2)  Service lines in the terminal span of a connection between an overhead line and a building or in a span between one building and another building shall be insulated conductors.

 

 

(3)  The point of attachment of a service line shall-

(a)        where connected to an overhead line, be at a support:

                Provided that a vertical service connection may be made elsewhere if it does not exceed 3.048 metres in length;

(b)        where connected to a building, be at a terminating device securely fixed to the building.

 

 

(4)  A conductor, other than an earth conductor, leading to or from a transformer or other apparatus at a pole-mounted substation shall, at all points below a height of 3.6576 metres from the ground, be insulated and, in the case of a high-voltage conductor, shall have earthed metal sheathing or earthed screening.

 

 

(5)  The height above ground of a line conductor, other than an extra-low-voltage, low-voltage or medium-voltage insulated line conductor, shall be not less than the appropriate height specified in the Third Schedule or such greater height as may be required either for compliance with regulation 12 or 15 or in terms of regulation 35.

 

 

(6)  Subject to the provisions of regulation 35, the height above ground of an extra-low-voltage, low-voltage or medium-voltage insulated line conductor shall be not less than-

(a)        where the line is above a road normally accessible to vehicular traffic, 5.4864 metres;

(b)        save as is provided in paragraph (c), where the line is not above a road normally accessible to vehicular traffic, 4.2672 metres;

(c)        in the case of a service line in the terminal span of a connection between an overhead line and a building or in a span between one building and another building, ten feet at any point where the line is not above a road normally accessible to vehicular traffic.

 

 

(7)  Where an earth conductor, stay-wire or cradle fitted between supports crosses a road normally accessible to vehicular traffic, the height thereof above the road surface shall be not less than 5.4864 metres.

 

 

(8)  Any minimum height or clearance required by these Regulations shall be maintained under any conditions of loading and temperature likely to occur in the area concerned.

 

 

34.  (1)  Where a consumer installs an unmetered service line on his premises or where a part of the consumer's installation is to be solely operated and controlled by the undertaker, and where the undertaker in terms of the Supply Regulations is required to ensure that such service line or such part of the installation-

(a)        is suitable for its intended purpose; and

(b)        is installed to prevent, as far as practicable, leakage of electricity to adjacent metal;

Unmetered service lines

 

the consumer shall comply with the directions of the undertaker in relation to the design and construction of such line or part.

 

 

(2)  Where the consumer has no effective means of cutting off the voltage to a line or part referred to in sub-regulation (1), he shall, if a disconnection is required, immediately notify the undertaker that it is required.

 

 

(3)  Where an undertaker has advised the consumer of any remedial measures necessary to correct any defect, deficiency or faulty condition which may exist in a line or part referred to in sub-regulation (1), the consumer shall take such measures to the satisfaction of the undertaker after the said line or part has been disconnected from the supply of electricity for the purpose.

 

 

35.    Where an overhead line crosses a permanent railway track having a gauge of not less than 15.24 centimetres, the following conditions shall apply:

(a)        the height above the rail of-

Overhead lines crossing railway tracks

 

(i)         a line conductor, shall be not less than the appropriate height specified in the Fourth Schedule;

 

 

(ii)        an earth conductor, stay-wire or cradle fitted between supports, shall be not less than 7.0104 metres;

(b)        there shall be no joints in the crossing span;

(c)        the crossing shall be made at right angles or as near thereto as practicable and shall be not less than 70 degrees unless permission in writing therefor has been obtained from the authority responsible for the operation of the railway;

(d)        the length of span at the crossing shall be as short as is reasonably practicable;

(e)        notwithstanding the provisions of sub-regulation (6) of regulation 37, line conductors used at the crossing shall be stranded with not less than 0.1613 square metres cross-sectional area copper or its equivalent conductivity.

 

 

36.  (l)  Where a high-voltage overhead line crosses an extra-low-voltage, low-voltage or medium-voltage overhead line or where line conductors forming part of such differing systems are erected on the same supports, provision shall be made to guard against the extra-low-voltage, low-voltage or medium-voltage system being charged above its normal voltage.

Different voltages in proximity

 

(2)  Where a pilot circuit is installed and operated as part of an overhead line system, the provisions of sub-regulation (1) shall apply thereto and such pilot circuit shall be installed and operated with due regard to any dangers which may arise from its use.

 

 

37.  (1)  In calculating the strength of the various constituent parts, including supports, of an overhead line, the following basic conditions shall be assumed:

(a)        a minimum temperature of 30 degrees Fahrenheit;

(b)        the wind pressure acting on the projected area of line conductors and supports not exceeding 12.192 metres in height shall be not less than 5.4 kilogramms per square metre and of those exceeding 12.192 metres but not exceeding 36.576 metres in height shall be not less than 6.75 kilogramms per square metre;

(c)        in the case of conductors, earth wires and round, elliptical or hexagonal poles used as supports, the area on which the pressure acts shall be taken as 60 per centum of the projected area and in the case of lattice or composite structures as one and one-half times the projected area of the constituent parts on one side.

Loading conditions and factors of safety

 

(2)  In the design of spans of over 121.92 metres, the assumed wind load on conductors and earth wires may be reduced to 70 per centum of the calculated load.

 

 

(3)  In the design of spans, due regard shall be given to the possibility of injurious conductor vibration by wind effects.

 

 

(4)  A support shall be designed so that the failing load under operating conditions shall be not less that the resultant of simultaneous horizontal and vertical loads calculated in accordance with the provisions of this regulation multiplied by the following factors:

(a)        where the support is of metal or concrete, 2.5;

(b)        where the support is of wood, 3.5.

 

 

(5)  Subject to the provisions of sub-regulation (6), the load in a line conductor, earth conductor, insulator, joint or cradle component or an associated fitting under operating conditions shall not exceed 50 per centum of its ultimate breaking load.

 

 

(6)  The minimum permissible size for a single line conductor shall be such as to have an ultimate breaking load of not less than 359.55 kilogramms and shall be not less in gauge than No. 10 British Standard Wire Gauge.

 

 

38.  (1)  Where metal-work is required to be earthed in accordance with the provisions of regulation 18, the earthing system of the overhead line with which it is associated shall be tested at at least one point by the consumer or by a person authorised by him-

(a)        before commissioning such overhead line;

(b)        and thereafter, at intervals of not more than six years;

and repaired if necessary.

Periodic testing and inspecting

 

(2)  The purpose of a test made in terms of sub-regulation (1) shall be to ensure that the leakage resulting from contact of negligible resistance between a line conductor and any metal-work connected with earth is sufficient to operate the protective device installed in terms of regulation 19 to make that line conductor dead.

 

 

(3)  An overhead line and its supports and any outdoor substation shall be inspected from ground level or above by the consumer or by a person authorised by him-

(a)        if erected before the 1st December, 1961, within six years of that date;

(b)        if erected on or after the 1st December, 1961, before commissioning;

(c)        and thereafter, at intervals not exceeding six years after the date of inspection referred to in paragraph (a) or (b), as the case may be;

and repaired if necessary.

 

 

(4)  A test or inspection made in terms of this regulation shall be recorded by the person making the test or inspection and such record shall be retained by the consumer until the next test or inspection is made.

 

 

39.    There shall be fixed in a prominent position at every pole-mounted substation a danger notice.

Danger notices

 

40.    In order to prevent, as far as is reasonably practicable, climbing which has not been authorised by the consumer, an anti-climbing device shall be fitted-

(a)        at every support for a pole-mounted substation;

(b)        at every support which has broken surfaces within 3.048 metres of the ground.

Unauthorised climbing of supports

 

PART VII

PROTECTIVE MULTIPLE EARTHING

 

 

41.    Where a consumer operates or is about to operate a transformer supplying low voltage or medium voltage to a single-phase two-wire or three-phase four-wire installation and is satisfied that protective multiple earthing is necessary in order to improve the general factor of safety in relation to earthing of metal-work, he may provide protective multiple earthing in accordance with the provisions of this Part.

Provision of protective multiple earthing

 

42.    Before providing protective multiple earthing, a consumer shall obtain the consent in writing of the Postmaster-General in terms of regulation 11 of the Lines Protection Regulations.

Consent of Postmaster-General.
Cap. 795 of the 1971 Edition

 

43.    Protective multiple earthing shall-

(a)        only be applied to the consumer's electric lines operating at low voltage or medium voltage;

(b)        when so applied, extend to every such line of a group supplied with electricity from a common transformer at the said voltage:

Limitations

 

    Provided that no such line shall be directly interconnected in a permanent manner with any other line supplied with electricity from any part of another system not similarly earthed.

 

 

44.    A transformer which is to supply the low voltage or medium voltage to an electric line provided with protective multiple earthing shall be so arranged that-

(a)        an earthing connection is taken from the metal-core or metal-work closely associated with the higher voltage winding to an earth electrode;

(b)        another earthing connection is taken from the neutral point on the low-voltage or medium-voltage winding to the same earth electrode or to another earth electrode with its own resistance area.

Connections at transformer

 

45.  (1)  Where a cable is used as an electric line provided with protective multiple earthing and is laid underground, such cable shall-

(a)        have a neutral conductor of the same material as, and be of a cross-sectional area not less than, any phase conductor; and

(b)        have metal sheathing or metal armouring.

Use of cables

 

(2)  The metal sheathing or metal armouring or, if the cable has both metal sheathing and metal armouring, the metal sheathing and metal armouring and the neutral conductor referred to in sub-regulation (1) shall be bonded together and also bonded to-

(a)        the earthing connection referred to in paragraph (b) of regulation 44 at the transformer position; and

(b)        an earth electrode or electrodes installed at points at or near the end of each line.

 

 

46.  (1)  Where an overhead line is used as an electric line provided with protective multiple earthing, such line shall-

(a)        have a neutral conductor of the same material as, and of a cross-sectional area not less than, any phase conductor; or

(b)        have two neutral conductors of the same material as, and each of a cross-sectional area not less than one half that of, any phase conductor.

Use of overhead lines

 

(2)  The neutral conductor or the two neutral conductors referred to in paragraph (a) or (b) of sub-regulation (l) shall be bonded to-

(a)        the earthing connection referred to in paragraph (b) of regulation 44 at the transformer position; and

(b)        earth electrodes installed at regular intervals, as far as practicable, along the route of the line, at branching points and at the final pole of each line.

 

 

47.  (1)  Where an underground cable and an overhead line are used in association with each other as an electric line provided with protective multiple earthing, the provisions of regulations 45 and 46 shall apply respectively to the cable and the overhead line except that the bonding to the earth connection at the transformer position referred to in paragraph (a) of sub-regulation (2) of regulation 45 or 46, as the case may be, may be omitted in the case of-

(a)        an underground cable which starts at a position remote from the transformer if that cable is fed from an overhead line which has such bonding to the earth connection at the transformer position;

(b)        an overhead line which starts at a position remote from the transformer if that line is fed from an underground cable which has such bonding to the earth connection at the transformer position.

Use of cables and overhead lines

 

(2)  At every point where an underground cable and an overhead line referred to in sub-regulation (1) are connected with each other, each neutral conductor of the said cable and line and the metal sheathing or metal armouring of the cable shall be bonded together.

 

 

48.    The provisions of regulation 44, 45, 46 or 47 shall not have been complied with until it has been established that the overall resistance to earth of a neutral conductor-

(a)        is such that the fuse, circuit-breaker or other protective device on the high-voltage side of the transformer will operate safely in the event of a breakdown between the transformer windings;

(b)        does not exceed ten ohms;

(c)        is such that the provisions of regulation 19, and of regulation 20 where applicable, can be complied with efficiently.

Overall resistance

 

49.    No fuse, switch, circuit-breaker, link or device, other than a bolted link, for interrupting continuity shall be inserted in a neutral or earth conductor used for protective multiple earthing purposes.

Neutral to be unbroken

 

50.    Where a supply of electricity is delivered from an electric line provided with protective multiple earthing to a separate installation, and whether such installation is to be operated and used by the consumer or by another person, the consumer, before providing an earth connection thereto, shall satisfy himself in regard to the separate installation that-

(a)        metal-work enclosing, supporting or in proximity to, or likely to come into contact with, any live conductor or live part is bonded together by one or more earth-continuity conductors; and

(b)        the overall resistance to earth of the earthing system is such that the provisions of regulation 19 can be complied with efficiently; and

(c)        the provisions of regulation 49 have been complied with.

Separate installation

 

PART VII

PRIVATE GENERATION AND SUPPLY

 

 

51.  (1)  Subject to the provisions of sub-regulation (2) of regulation 4, the provisions of this Part shall apply to every private owner.

Private ownership

 

(2)  The provisions of Parts II, III, IV, V, VI and VIII shall, mutatis mutandis, apply to a private owner and to his electrical installation as they apply to a consumer and a consumer's installation.

 

 

52.  (1)  A private owner shall erect and maintain a switchboard for each generator to control supply therefrom and shall fit to each switchboard, as a minimum requirement-

(a)        the appropriate supply controls and protective apparatus specified in Part I of the Fifth Schedule;

(b)        where two or more private generators are to be operated in parallel-

Protection of generators

 

(i)         if it is a two-wire system, a reverse-current trip in series with the live conductor of each generator;

 

 

(ii)        if it is a three-wire system, a reverse-current trip in series with each outer conductor of each generator;

 

 

(iii)       if they are compound generators, an equaliser connection by means of-

 

 

A.        a single-pole switch from each generator to an equaliser bus-bar so arranged that each switch is interlocked so that it must be closed before the main switch is closed and opened after the main switch is opened; or

 

 

B.        a multi-pole linked-switch arranged and interlocked to perform the same sequence of operations as described for single-pole switches;

 

 

            with the operating coil of a circuit-breaker connected to a pole other than that to which the equaliser connection is made;

(c)        where a direct-current generator is connected in parallel with a secondary battery-

 

 

(i)         a reverse-current trip, which may be of the cut-out type, connected between the generator and the battery;

 

 

(ii)        safe means for isolating the battery from the generator;

 

 

(iii)       protection for the battery by means of a fuse or circuit-breaker against excessive charge or discharge currents;

 

 

(iv)       an ammeter to measure the current supplied by the generator;

 

 

(v)        an ammeter with a mid-point zero or so switched as to measure separately the charge and discharge currents of the battery;

 

 

(vi)       a voltmeter arranged to measure separately the voltage of the generator and of the battery;

(d)        where compound generators are operated in parallel, an ammeter connected to the pole other than that to which the equaliser connection is made;

(e)        where a direct-current generator operates a three-wire system, an arrangement to prevent the balancer being disconnected whilst the outer conductors are live;

(f)         the appropriate instruments specified in Part II of the Fifth Schedule;

(g)        where an alternating-current generator is operated-

 

 

(i)         a speed indicator for the prime-mover, or a frequency indicator;

 

 

(ii)        if two or more generators are to be operated in parallel, a synchronising device.

 

 

(2)  Where an instrument fitted to the switchboard in terms of sub-regulation (1) is required to make more than one measurement, provision for this shall be made by a suitable switch or plug.

 

 

(3)  If the generator of a private owner is arranged for automatic starting or for remote control, the prime-mover shall have local over-riding control for stopping the prime-mover and for preventing automatic starting-

(a)        fixed nearby; and

(b)        indelibly labelled with operating instructions.

 

 

53.    A private owner shall-

(a)        where liquid or gaseous fuel for the generating plant is piped from outside the plant room, provide a quick-acting valve to cut off the supply of fuel with the valve-

Fire precautions

 

(i)         fixed near the door to the plant room in a conspicuous position; and

 

 

(ii)        indelibly labelled with operating instructions;

(b)        arrange to trap or drain and disperse safely any leaking or surplus fuel and ensure that none is permitted to enter any sewer.

 

 

54.  (1)  A private owner shall ensure that any room in which his generating plant is to be erected and maintained-

(a)        is of such size that the plant can be easily and adequately serviced and maintained;

(b)        is adequately ventilated;

(c)        is provided with the exhaust pipes or ducts necessary to discharge exhaust fumes from the room to the outside air and clear of any window, door or fresh air intake of any building.

Plant rooms

 

(2)  A plant room described in sub-regulation (1) shall have adequate artificial lighting in addition to any natural lighting, and discharge-lighting shall not be used in a position where it may cause rotating machines to appear to be stationary.

 

 

55.  (1)  A private owner whose generator is connected with a secondary battery installation shall erect and maintain a switchboard for that installation and shall fit to the switchboard, as a minimum, requirement-

(a)        safe means-

Protection of batteries

 

(i)         for isolating the battery from the load or from the charging circuit or simultaneously from both;

 

 

(ii)        where the charging circuit is arranged to share the load, for isolating the charging circuit from the battery and from the load;

(b)        a suitable fuse or circuit-breaker with overload trip to protect-

 

 

(i)         the battery from excess charge and discharge currents;

 

 

(ii)        the charge circuit from excess charge currents;

(c)        where the circuit is not a rectifier circuit which prevents a reversal of current, a reverse-current trip, which may be of the cut-out type, connected between the charging circuit and the battery;

(d)        an ammeter with a mid-point zero or so switched as to measure separately the charge and discharge currents;

(e)        a voltmeter with an "off" position to prevent continuous discharge and to indicate-

 

 

(i)         battery terminal voltage;

 

 

(ii)        where the charging circuit has no cut-out, the voltage of the charging circuit separately from the battery terminal voltage;

(f)         where the charging circuit shares the load with the battery, an ammeter to measure the current output of the charging circuit.

 

 

56.  (1)  A battery in a battery installation connected with the generator of a private owner shall-

(a)        have insulated supports for each cell of glass or vitreous-porcelain which is part of the container;

(b)        have insulated battery stands;

(c)        have connecting bolts-

Installation of batteries

 

(i)         of a non-corrosive type; or

 

 

(ii)        coated with petroleum jelly;

(d)        have spray arresters on open cells;

(e)        if not portable, contain no celluloid in its construction;

(f)         if portable and with celluloid in its construction, have suitable safeguards at the charging location to prevent ignition of the celluloid and the spread of fire.

 

 

(2)  A room containing a battery in a battery installation connected with the generator of a private owner shall-

(a)        be adequately ventilated to the outside air;

(b)        where sulphuric acid is used as an electrolyte, have its construction and fittings-

 

 

(i)         of non-corrosive material; or

 

 

(ii)        painted with acid-resisting paint.

 

 

57.    All machinery, switchgear and instruments associated with the generation and supply of electricity of a private owner shall be indelibly labelled so as to indicate their functions and ratings.

Labelling

 

58.    The plant of a private owner shall not be interconnected, either directly or indirectly, with the electrical works, lines or cables of an undertaker or other person unless-

(a)        there is an agreement in writing for such interconnection between the private owner and the owner of the said works, lines or cables; and

(b)        adequate safeguards are installed to prevent accidental or uncontrolled interconnection.

Inter-connection

 

PART VIII

OFFENCES AND PENALTIES

 

 

59.  (1)  Subject to the provisions of sub-regulations (2) and (3) of regulation 4, a consumer or a private owner who erects or operates an electrical installation for or in connection with the generation, transmission, distribution, connection, installation and use of electricity, whether on his premises or elsewhere, where such installation is constructed, operated, maintained, repaired, tested or inspected otherwise than in accordance with the provisions of these Regulations shall be guilty of an offence.

Offences and penalties

 

(2)  Any person who is guilty of an offence in terms of sub-regulation (1) shall be liable to a fine not exceeding three thousand penalty units or, in default of payment, to imprisonment for a period not exceeding twelve months.

(As amended by Act No. 13 of 1994)

 

 

FIRST SCHEDULE
(Regulations 13 and 15)

MINIMUM SECTION CLEARANCES

 

 

 

                              Minimum clearance from any point on
Normal operating voltageor about the permanent equipment
between bare line conductorswhere a man may be required to stand
                                     (measured from the position of the
                                                                                   feet)-

 

                                                                                 To the nearest
                                                                              part not at earth
                                                      To the nearest    potential of an
                                                    unscreened live             insulator
                                                   conductor in air       supporting a
                                                                                 live conductor

                                                                  metres                metres

 1.   Not exceeding 15,000 volts                                                  2.62128      2.4384

 2.   Exceeding 15,000 volts but                                                  2.7432        2.4384
         not exceeding 33,000 volts

 3.   Exceeding 33,000 volts but                                                  2.92608      2.4384
         not exceeding 44,000 volts

 4.   Exceeding 44,000 volts but                                                  3.048          2.4384
         not exceeding 66,000 volts

 5.   Exceeding 66,000 volts but                                                  3.23088      2.4384
         not exceeding 88,000 volts

 6.   Exceeding 88,000 volts but                                                  3.3528        2.4384
         not exceeding 110,000 volts

 7.   Exceeding 110,000 volts but                                                3.53568      2.4384
          not exceeding 132,000 volts

 8.   Exceeding 132,000 volts but                                                3.84048      2.4384
         not exceeding 165,000 volts

 9.   Exceeding 165,000 volts but                                                4.2672        2.4384
         not exceeding 220,000 volts

10.  Exceeding 220,000 volts but                                                4.572          2.4384
         not exceeding 275,000 volts

11.  Exceeding 275,000 volts but                                                5.1816        2.4384
         not exceeding 330,000 volts

 

For the purposes of this Schedule-

(a)     the above provisions concern the means of access for works which are permanently available, such as fixed ladders or platforms attached to structures. The means of access shall also comprise the structures themselves and the tops of circuit-breakers or transformers if a man is required to stand on them to carry out work. Subject to the provisions of paragraph (b), the provisions do not apply to portables ladders, cradles or similar equipment, the use of which is governed by the general instructions issued by the consumer in terms of regulation 13;

(b)    portable ladders and platforms specially designed for specific maintenance work, and so arranged that they cannot readily be employed in any way other than that intended, shall be considered as permanent means of access for the purpose of safety clearances.

 

 

 

SECOND SCHEDULE
(Regulation 14)

 

THE ELECTRICITY ACT

 

CERTIFICATE OF INSPECTION AND TEST

 

 

 

    Notice to an undertaker from a consumer certifying the condition of the consumer's electrical installation.

From   

(Name and address of consumer)

To       

(Name and address of undertaker)

    I attach hereto a certificate in respect of the condition of my electrical installation.

Signed Date ...................................  

                                (Consumer's signature)

_________________________

 

I          

(Name and address of certifier)

of        

(Name and address of firm or company)

am a/an           

(Occupation, trade or profession)

and I hereby declare that I am competent to make and sign this certificate and do hereby certify as follows:

 

1.  That the electrical installation in entirety/in part comprising

           

(Description of part)

     at   

(Address of premises)

     (a)  was installed by me/by           

(Name and address of contractor or other person)

                  and

     (b)  was inspected and tested by me;

 

     fully in accordance with the recommendations contained in an edition current at the date of this certificate of the Safety Code for the electrical wiring of premises issued by the Standards Association of Zambia in respect of those sections of the installation falling within the scope of the Safety Code.

 

2.  That to the best of my knowledge and belief the said electrical installation in entirety/in respect of the part described-

     (a)  complies with the Wiring Regulations; and

     (b)  is in a fit and proper condition to operate safely if connected to the intended supply of electricity; and

     (c)  can be so connected without risk of a dangerous electrical leakage occurring.

             Signature of Certifier

             Witness

Dated at           on .................................................., 19 ............

 

 

 

THIRD SCHEDULE
(Regulation 52)

MINIMUM HEIGHTS OF OVERHEAD LINES

 

 

 

                                                                             In any position
Normal operating voltage betweenOver roads normallyexcept where
  line conductors                          accessible tootherwise specified
                                               vehicular trafficin these Regulations

 

1.  Not exceeding 650 volts. .                      5.4864 metres      4.8768 metres

2.  Exceeding 650 volts but not
     exceeding 33,000 volts    . .                      5.7912 metres      5.1816 metres

3.  Exceeding 33,000 volts but not
     exceeding 88,000 volts    . .                      6.096 metres        6.096 metres

4.  Exceeding 88,000 volts but not                
     exceeding 132,000 volts  . .                      6.7056 metres      6.7056 metres

5.  Exceeding 132,000 volts but not
     exceeding 275,000 volts  . .                      7.0104 metres      7.0104 metres

6.  Exceeding 275,000 volts. .                      7.3152 metres      7.3152 metres

 

 

 

FOURTH SCHEDULE
(Regulation 35)

MINIMUM HEIGHTS OF OVERHEAD LINES CROSSING RAILWAY TRACKS

 

 

 

                                                                                  Minimum height
Normal operating voltage between line conductors                            above rail

 

1.  Not exceeding 33,000 volts    . .       . .       . .       . .                   . .  . .         7.62 metres

2.  Exceeding 33,000 volts but not exceeding 88,000 volts          . .  . .         7.9248 metres

3.  Exceeding 88,000 volts but not exceeding 132,000 volts        . .  . .         8.5344 metres

4.  Exceeding 132,000 volts but not exceeding 275,000 volts      . .  . .         8.8392 metres

5.  Exceeding 275,000 volts                  . .       . .       . .                   . .  . .         9.144 metres

 

 

 

FIFTH SCHEDULE
(Regulation 52)

MINIMUM REQUIREMENTS FOR PROTECTION OF PRIVATE GENERATORS

 

 

PART I

SWITCHBOARD SUPPLY CONTROLS AND PROTECTIVE APPARATUS

                                         Number of poles
                                           to be broken by                 Position of
                                            circuit-breaker          circuit-breaker
               System of supply            or switch                       or fuse

 

1.  Two-wire alternating current or          1                        In non-earthed
     direct current, earthed at either pole.                            conductor.

2.  Two-wire, alternating current or         2                        In each conductor.
     direct current, not earthed at either
     pole.

3.  Three-wire, single-phase, alternating   2                        In each outer
     current or direct current.                                               conductor

4.  Three-wire, three-phase, alternating    3                        In each non-
     current or four-wire, three-phase,                                  earthed conductor.
     alternating current.

 

PART II

INSTRUMENTS FOR A SWITCHBOARD

          Type of system     One generator only     More than one generator

1.  Two-wire, alternating    (a)                           an ammeter; and       (i)         an ammeter for each
     current or direct current                                         generator: and
 

                                       (b)                                a voltmeter    (ii)        a voltmeter to measure
                                                                                  the voltage of any
                                                                                  generator; and

                                                                           (iii)  if generators are
                                                                                  paralleled, a voltmeter to
                                                                                  measure the bus-bar voltage.

2.  Three-wire, single-    (a)                                an ammeter to           (i)         an ammeter for each
     phase, alternating           measure the cur-            generator to measure
     current or direct             rent in each outer           the current in each
     current                           conductor; and              outer conductor; and

                                       (b)                                two voltmeters          (ii)        two voltmeters each
                                           each connected              connected between
                                           between an outer           an outer conductor
                                           conductor and               and neutral of the
                                           neutral                           bus-bars: and

                                                                           (iii)  if generators are
                                                                                  paralleled two voltmeters,
                                                                                  each connected between
                                                                                  an outer conductor and
                                                                                  neutral, to measure the
                                                                                  voltage of any generator.

3.  Three-wire, three-     (a)                                an ammeter to           (i)         an ammeter for each
     phase, alternating           measure the current          generator to measure
     current or four-wire,      in each phase; and         the current in each
     three-phase alternating                                           phase; and
     current

                                       (b)                                a voltmeter to           (ii)        a voltmeter to
                                           measure the line             measure the line
                                           voltage                           voltage of each
                                                                                  generator; and

                                                                           (iii)  if generators
                                                                                  are paralleled, a
                                                                                  voltmeter to
                                                                                  measure the bus-
                                                                                  bar voltage.